Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Helical CT Reconstruction from Sparse-view Data through Exploiting the 3D Anatomical Structure Sparsity

Yongbo Wang; Gaofeng Chen; Xi Tao; Zhaoying Bian; Dong Zeng; Habib Zaidi; Ji He; Jianhua Ma (2021). IEEE Access

DOI 10.1109/access.2021.3049181

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Sparse-view scanning has great potential for realizing ultra-low-dose computed tomography (CT) examination. However, noise and artifacts in reconstructed images are big obstacles, which must be handled to maintain the diagnosis accuracy. Existing sparse-view CT reconstruction algorithms were usually designed for circular imaging geometry, whereas the helical imaging geometry is commonly adopted in the clinic. In this paper, we show that the sparse-view helical CT (SHCT) images contain not only noise and artifacts but also severe anatomical distortions. These troubles reduce the applicability of existing sparse-view CT reconstruction algorithms. To deal with this problem, we analyzed the three-dimensional (3D) anatomical structure sparsity in SHCT images. Based on the analyses, we proposed a tensor decomposition and anisotropic total variation regularization model (TDATV) for SHCT reconstruction. Specifically, the tensor decomposition works on nonlocal cube groups to exploit the anatomical structure redundancy; the anisotropic total variation works on the whole volume to exploit the structural piecewise-smooth. Finally, an alternating direction method of multipliers is developed to solve the TDATV model. To our knowledge, the paper presents the first work investigating the reconstruction of sparse-view helical CT. The TDATV model was validated through digital phantom, physical phantom, and clinical patient studies. The results reveal that SHCT could serve as a potential solution for reducing HCT radiation dose to ultra-low level by using the proposed TDATV model.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=14; title_english_function_words=3; title_english_share=0.2143; title_reads=english; abstract_words=231; abstract_english_function_words=73; abstract_english_share=0.3160; abstract_reads=english; language_check=metadata_listed