Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Image quality of ultra-low-dose dual-source CT angiography using high-pitch spiral acquisition and iterative reconstruction in young children with congenital heart disease

Minwen Zheng; Hongliang Zhao; Jian Xu; Yongjie Wu; Jian Li (2013). Journal of Cardiovascular Computed Tomography

DOI 10.1016/j.jcct.2013.11.005

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

BACKGROUND: Obtaining diagnostic CT image quality with ultra-low radiation dose in young children with congenital heart disease remains challenging. OBJECTIVE: We evaluated the feasibility and image quality of prospectively electrocardiogram (ECG)-triggered high-pitch spiral acquisition with iterative reconstruction for pediatric cardiovascular CT angiography. METHODS: Sixty-two consecutive pediatric patients younger than 2 years with congenital heart disease underwent prospectively ECG-triggered high-pitch spiral dual-source CT acquisition. Patients were randomly assigned into 2 groups: full tube current (40-70 mAs) scans with filtered back projection reconstruction (group A) and half tube current (20-35 mAs) scans with sinogram-affirmed iterative reconstruction (group B). Attenuation, noise, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and subjective image quality were compared between the 2 groups. Effective radiation dose was also estimated for both groups. RESULTS: No significant difference was found in the attenuation, image noise, SNR, and CNR between the 2 groups in the same evaluated anatomic regions, whereas the attenuation and image noise were slightly lower, and the SNR and CNR were slightly higher in group B. No significant difference was found in subjective image quality between the 2 groups (4.27 ± 0.73 vs. 4.34 ± 0.42; P = .813). Effective dose was 0.06 ± 0.03 mSv in group B and 0.13 ± 0.04 mSv in group A, reflecting dose savings of 53.8% by using iterative reconstruction. CONCLUSIONS: A combination of prospectively ECG-triggered high-pitch spiral acquisition, low tube current, and iterative reconstruction may offer diagnostic image quality in pediatric cardiovascular CT angiography with effective radiation dose < 0.1 mSv.

From PubMed.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=25; title_english_function_words=4; title_english_share=0.1600; title_reads=english; abstract_words=239; abstract_english_function_words=60; abstract_english_share=0.2510; abstract_reads=english; language_check=metadata_listed