Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Wavelet Compression of Low-Dose Chest CT Data: Effect on Lung Nodule Detection
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
PURPOSE: To assess the effect of using a lossy Joint Photographic Experts Group standard for wavelet image compression, JPEG2000, on pulmonary nodule detection at low-dose computed tomography (CT). MATERIALS AND METHODS: One hundred sets of lung CT data ("cases") were compressed to 30:1, 20:1, and 10:1 levels by using a wavelet-based JPEG2000 method, resulting in 400 test cases. Each case consisted of nine 1.25-mm sections that had been obtained with 20-40 mAs. Four thoracic radiologists independently interpreted the test case images. Performance was measured by using area under the receiver operating characteristic (ROC) curve (Az) and conventional sensitivity and specificity analyses. RESULTS: There were 51 cases with and 49 without lung nodules. Az values were 0.984, 0.988, 0.972, 0.921, respectively, for original and 10:1, 20:1, and 30:1 compressed images. Az values decreased significantly at 30:1 (P =.014) but not at 10:1 compression, with a trend toward significant decrease at 20:1 (P =.051). Specificity values were unaffected by compression (>98.0% at all compression levels). Sensitivity values were 86.3% (176 of 204 test cases with nodules), 77.9% (159 of 204 cases), 76.5% (156 of 204 cases), and 70.1% (143 of 204 cases), respectively, for original and 10:1, 20:1, and 30:1 compressed images. Results of logistic regression model analysis confirmed the significant effects of compression rate and nodule attenuation, size, and location on sensitivity (P <.05). CONCLUSION: While no reduction in nodule detection at 10:1 compression levels was demonstrated by using ROC analysis, a significant decrease in sensitivity was identified. Further investigation is needed before widespread use of image compression technology in low-dose chest CT can be recommended.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=13; title_english_function_words=2; title_english_share=0.1538; title_reads=english; abstract_words=231; abstract_english_function_words=79; abstract_english_share=0.3420; abstract_reads=english; language_check=metadata_listed