Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

PPORLD-EDNetLDCT: A Proximal Policy Optimization-based reinforcement learning framework for adaptive low-dose CT denoising

Debopom Sutradhar; Ripon Kumar Debnath; Mohaimenul Azam Khan Raiaan; Yan Zhang; Reem E. Mohamed; Sami Azam (2026). Biomedical Signal Processing and Control

DOI 10.1016/j.bspc.2026.111403

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Low-dose computed tomography (LDCT) is critical for minimizing radiation exposure, but it often leads to increased noise and reduced image quality. Traditional denoising methods, such as iterative optimization or supervised learning, often fail to preserve image quality. To address these challenges, we introduce PPORLD-EDNetLDCT, a reinforcement learning-based (RL) approach with Encoder–Decoder for LDCT. Our method utilizes a dynamic RL-based approach in which the Proximal Policy Optimization (PPO) algorithm is employed to optimize the denoising policy during training, guided by image quality feedback in a custom gym environment, while inference is performed using the trained fixed-parameter encoder–decoder model. The experimental results on the low dose CT image and projection dataset demonstrate that the proposed PPORLD-EDNetLDCT model outperforms traditional denoising techniques and other DL-based methods, achieving a peak signal-to-noise ratio of 41.87, a structural similarity index measure of 0.9814 and a root mean squared error of 0.00236. Moreover, in NIH-AAPM-Mayo Clinic Low Dose CT Challenge dataset our method achieved a PSNR of 41.52, SSIM of 0.9723 and RMSE of 0.0051. Furthermore, we validated the quality of denoising using a classification task in the COVID-19 LDCT dataset, where the images processed by our method improved the classification accuracy to 94%, achieving 4% higher accuracy compared to denoising without RL-based denoising.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=16; title_english_function_words=2; title_english_share=0.1250; title_reads=english; abstract_words=213; abstract_english_function_words=66; abstract_english_share=0.3099; abstract_reads=english; language_check=metadata_listed