Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

An application study of low-dose computed tomography perfusion imaging (LDCTPI) in breast cancer and breast fibroadenoma

Yougen Cheng; Zongqiong Sun; Hong-Xia Zhang; Guoqun Mao (2018). Journal of X-Ray Science and Technology

DOI 10.3233/xst-18377

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

PURPOSE: To explore the characteristics of breast cancer and breast fibroadenoma using low-dose computed tomography perfusion imaging (LDCTPI) including specific perfusion parameter values, and seek the potential clinical applications in cancer prognosis assessment. MATERIALS AND METHODS: Fifty patients including 30 diagnosed with breast cancer and 20 with breast fibroadenoma, as well as 15 control subjects with normal breasts were studied prospectively using LDCTPI examinations. The acquired volumetric imaging data were used for calculation, mapping and analysis by using a body tumor perfusion protocol in the CT perfusion software to measure 4 parameters: blood flow (BF), blood volume (BV), mean transit time (MTT), and the permeability surface (PS) area product. Statistical data analysis was then performed to distinguish the difference of the 4 parameter values among normal control, breast cancer and breast fibroadenoma cases. RESULTS: The mean perfusion values of 15 normal controls were as follows: BF, 20.03±4.08 mL/100 g/min; BV, 4.53±0.95 mL/100 g; MTT, 5.90±0.82 s; and PS, 9.25±1.18 mL/100 g/min. The mean perfusion values of 30 cancer patients were as follows: BF, 56.67±6.59 mL/100 g/min; BV, 5.82±0.68 mL/100 g; MTT, 6.01±0.82 s; and PS, 24.95±5.05 mL/100 g/min. The mean perfusion values of 20 patients with breast fibroadenoma were as follows: BF, 46.24±6.65 mL/100 g/min; BV, 5.07±0.73 mL/100 g; MTT, 7.51±0.62 s; and PS, 16.73±6.48 mL/100 g/min. Comparing the 3 groups, differences were all statistically significant for BF, BV, MTT and PS values (p < 0.05, respectively); The BF, BV, PS values were highest in group of cancer patients, while the MTT value was highest in group of patients diagnosed with breast fibroadenoma. CONCLUSION: Breast CT perfusion imaging is a promising functional imaging technology in breast cancer diagnosis, which can provide valuable quantitative imaging markers to assist evaluation of breast tumors.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=17; title_english_function_words=4; title_english_share=0.2353; title_reads=english; abstract_words=275; abstract_english_function_words=72; abstract_english_share=0.2618; abstract_reads=english; language_check=metadata_listed