Imaging quality and diagnostic reliability of low-dose computed tomography lumbar spine for evaluating patients with spinal disorders
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
BACKGROUND CONTEXT: Computed tomography (CT) scans of the lumbar spine (CTLS) have demonstrated a higher level of accuracy than plain films and have been used to assess patients with spinal disorder when magnetic resonance imaging is not available. Nevertheless, radiation exposure remains a serious safety concern. Iterative reconstruction (IR) decreases the CT radiation dose for diagnostic imaging. However, the feasibility of using IR in CTLS is unclear. PURPOSE: To evaluate the imaging quality and diagnostic reliability of CTLS with IR. STUDY DESIGN: A prospective study. PATIENT SAMPLE: All patients from outpatient departments who suffered from spinal disorders and were referred for CTLS. OUTCOME MEASURES: In acquired CT images, the signal-to-noise ratio (SNR) of the dural sac (DS), intervertebral disc (IVD), psoas muscle (PM), and L5 vertebral body, the contrast-to-noise ratio between the DS and IVD (D-D CNR), and the subjective imaging qualities were compared across groups. Interobserver agreement was evaluated with kappa values. METHODS: Patients receiving low radiation CTLS were divided into three groups. A 150 mAs tube current with 120 kVp tube voltage was used with Group A and a 230 mAs tube current with 100 kVp tube voltage with Group B. Intended end radiation exposure was 50% less than that of the control group. Tube modulation was active for all groups. The images of the two low-radiation groups were reconstructed by IR; those of the control group by filtered back-projection (FBP). RESULTS: The SNRs of the DS, IVD, PM, BM, and D-D CNR of Group A were not inferior to those of the control group. All SNRs and D-D CNRs for Group B were inferior to those of the control group. Except for that of the facet joint, all subjective imaging ratings for anatomic regions were equivalent between Groups A and B. Interobserver agreement was highest for the control group (0.72-0.88), followed by Group A (0.69-0.83) and B (0.55-0.83). CONCLUSIONS: Fifty percent tube current reduction combined with IR provides equivalent diagnostic accuracy and improved patient safety when compared with conventional CTLS. Our results support its use as a screening tool. With the tube modulation technique, further adjustments in weighting IR and FBP algorithms based on body mass index become unnecessary.
From PubMed.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=18; title_english_function_words=4; title_english_share=0.2222; title_reads=english; abstract_words=363; abstract_english_function_words=129; abstract_english_share=0.3554; abstract_reads=english; language_check=metadata_listed