Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
A multi-scale cross aggregation network for joint denoising and super-resolution of low-dose CT images
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
Introduction Low-dose computed tomography (LDCT) reduces radiation exposure but often introduces signal-dependent noise and spatially varying streak artifacts that obscure subtle anatomical structures. Existing restoration methods struggle to suppress these degradations while maintaining long-range anatomical consistency and recovering high-frequency details. To address these challenges, we propose MSCANet, a Multi-Scale Cross Aggregation Network for joint LDCT denoising and super-resolution. Methods MSCANet integrates three complementary components. The Token Fusion and Aggregation Block combines global structural context and local texture information through prototype-guided feature aggregation. Region-Aware Self-Attention models local contextual relationships with overlapping receptive fields, while the Multi-Scale Deformable Attention Module employs learnable sampling offsets to characterize irregular structures and spatially varying artifacts. We evaluated MSCANet on the public 3D-IRCADB and PANCREAS datasets at × 2 and × 4 scaling factors and compared it with nine representative image-restoration methods. An additional qualitative evaluation was conducted on a self-collected clinical CT dataset comprising 2,544 slices from 17 patients. Reconstruction quality was assessed using peak signal-to-noise ratio (PSNR), structural similarity index measure (SSIM), contrast-to-noise ratio (CNR), and Learned Perceptual Image Patch Similarity (LPIPS). Model efficiency was evaluated using the parameter count and floating-point operations (FLOPs). Results On the public datasets, MSCANet achieved the best PSNR, SSIM, and CNR among the compared methods at both scaling factors. At × 4 , it obtained PSNR/SSIM/CNR values of 31.9514 dB/0.8383/0.7592 on 3D-IRCADB and 32.1740 dB/0.8422/1.1692 on PANCREAS. These results corresponded to PSNR gains of 0.2320 and 0.0922 dB over the respective second-best methods. MSCANet also achieved the lowest LPIPS value of 0.0517 while requiring only 11.03 million parameters and 142.72 GFLOPs. Qualitative comparisons on the self-collected dataset across axial, coronal, and sagittal views showed clearer tissue boundaries and more continuous anatomical structures after restoration. Ablation studies further confirmed the complementary contributions of the proposed components. Conclusion MSCANet provides an effective balance between noise suppression, artifact reduction, anatomical structure preservation, and computational efficiency for joint LDCT denoising and super-resolution. The results support its potential for LDCT image restoration, while observer-based assessment and downstream clinical validation are still required to establish its diagnostic value.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=17; title_english_function_words=4; title_english_share=0.2353; title_reads=english; abstract_words=353; abstract_english_function_words=90; abstract_english_share=0.2550; abstract_reads=english; language_check=metadata_listed