Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Volumetry versus linear diameter lung nodule measurement: an ultra-low-dose computed tomography lung cancer screening study

Maria M. Suchilova; Ivan Andreevich Blokhin; Olga O. Aleshina; Victor А. Gombolevskiy; Roman V. Reshetnikov; Viktor Yu. Bosin; Olga V. Omelyanskaya; Anton V. Vladzymyrskyy (2023). Digital Diagnostics

DOI 10.17816/dd117481

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

BACKGROUND: The DutchBelgian Randomized Lung Cancer Screening Trial (NELSON) used a volume-based protocol and significantly reduced the prevalence of false-positive results (2.1%). AIM: To compare the performance of manual linear diameter and semi-automated volumetric nodule measurement in the pilot project Moscow Lung Cancer Screening ultra-low-dose computed tomography pilot study. MATERIALS AND METHODS: The study included individuals with a lung nodule of at least 4 mm on baseline-computed tomography of the Moscow lung cancer screening between February 2017 and February 2018, without verified lung cancer diagnosis until 2020. The radiation dose was selected individually and did not exceed 1 mSv. All scans were assessed by three blinded readers to measure the maximum and minimum transversal nodule diameter and extrapolated volume. As a reference value of size and volume, the average value from the results of expert measurements was obtained. A false-positive nodule was defined as a nodule 6 mm/100 mm3 and a false-negative nodule as a nodule 6 mm/100 mm3. RESULTS: Overall, 293 patients were included (166 men; mean age, 64.6 5.3years); 199 lung nodules were 6 mm/100 mm3 and 94 were 6 mm/100 mm3. Regarding volumetric measurements, 32 [10.9%; 4 false-positive, 28 false-negative], 29 [9.9%; 17 false-positive, 12 false-negative], and 30 [10.2%; 6 false-positive, 24 false-negative] nodule discrepancies were reported by readers 1, 2, and 3 respectively. For linear diameter measurement, 92 [65.5%; 107 false-positive, 85 false-negative], 146 [49.8%; 58 false-positive, 88 false-negative], and 102 [34.8%; 23 false-positive, 79 false-negative] nodule discrepancies were reported by readers 1, 2, and 3 respectively. CONCLUSIONS: The use of lung nodule volumetry strongly reduces the number of false-positive and false-negative nodules compared with nodule diameter measurements, in an ultra-low-dose computed tomography lung cancer screening program.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=17; title_english_function_words=1; title_english_share=0.0588; title_reads=not_english; abstract_words=260; abstract_english_function_words=74; abstract_english_share=0.2846; abstract_reads=english; language_check=metadata_listed