Optimization of Low-Dose CT Protocols for Lung Cancer Screening: A Comprehensive Analysis Using Clinical and Phantom Data
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
Abstract Objective: To optimize Low-Dose Computed Tomography (LDCT) protocols for lung cancer screening by evaluating radiation dose, image quality, and the accuracy of Hounsfield Unit (HU) measurements across various technical settings. Methods: The study compared clinical data with phantom experiments. Clinical analysis was performed on 190 patients (95 standard-dose and 95 low-dose CT) scanned with a 128-slice CT system. Radiation metrics (CTDIvol, DLP, SSDE, and Effective Dose) and image quality (SNR, CNR, and noise) were recorded. In the experimental phase, a CT Tissue Equivalent (TE) phantom with 18 tissue-mimicking inserts was scanned using nine different protocols (mA: 11–350; kV: 70–140) to determine the correlation between electron density and CT numbers. Results: The LDCT protocols achieved a radiation dose reduction of over 70% compared to standard-dose protocols (p < 0.05). Although image noise increased at lower doses, CNR and SNR remained clinically acceptable for screening purposes. Phantom analysis demonstrated a strong linear correlation (R² > 0.99) between electron density and CT numbers across all protocols. Two specific settings, 22 mA/120 kV and 30 mA/100 kV, were identified as the most effective for balancing dose reduction with quantitative accuracy. Conclusion: Optimized LDCT protocols can significantly reduce radiation exposure while maintaining the reliability of CT numbers. The use of a tissue-equivalent phantom is a valid method for establishing screening protocols that adhere to the ALARA principle. However, a visual assessment of image quality is recommended to ensure that diagnostic clarity and essential anatomical details are preserved before these optimized protocols are implemented in routine screening. Keywords: Low-Dose CT (LDCT), Optimization, Lung Cancer Screening, Radiation Dose, Image Quality, CT Tissue Equivalent Phantom.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=18; title_english_function_words=4; title_english_share=0.2222; title_reads=english; abstract_words=262; abstract_english_function_words=73; abstract_english_share=0.2786; abstract_reads=english; language_check=metadata_listed