Optimization of Low-Dose CT Protocols for Lung Cancer Screening: A Comprehensive Analysis Using Clinical and Phantom Data

Pichan Kaewpookum; Natthida Malithong; Sitthiluck Luckhan; Siranat Butalome; Korndech Pattanasittiwong (2026). Ramkhamhaeng International Journal of Science and Technology

Source record

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Abstract Objective: To optimize Low-Dose Computed Tomography (LDCT) protocols for lung cancer screening by evaluating radiation dose, image quality, and the accuracy of Hounsfield Unit (HU) measurements across various technical settings. Methods: The study compared clinical data with phantom experiments. Clinical analysis was performed on 190 patients (95 standard-dose and 95 low-dose CT) scanned with a 128-slice CT system. Radiation metrics (CTDIvol, DLP, SSDE, and Effective Dose) and image quality (SNR, CNR, and noise) were recorded. In the experimental phase, a CT Tissue Equivalent (TE) phantom with 18 tissue-mimicking inserts was scanned using nine different protocols (mA: 11–350; kV: 70–140) to determine the correlation between electron density and CT numbers. Results: The LDCT protocols achieved a radiation dose reduction of over 70% compared to standard-dose protocols (p < 0.05). Although image noise increased at lower doses, CNR and SNR remained clinically acceptable for screening purposes. Phantom analysis demonstrated a strong linear correlation (R² > 0.99) between electron density and CT numbers across all protocols. Two specific settings, 22 mA/120 kV and 30 mA/100 kV, were identified as the most effective for balancing dose reduction with quantitative accuracy. Conclusion: Optimized LDCT protocols can significantly reduce radiation exposure while maintaining the reliability of CT numbers. The use of a tissue-equivalent phantom is a valid method for establishing screening protocols that adhere to the ALARA principle. However, a visual assessment of image quality is recommended to ensure that diagnostic clarity and essential anatomical details are preserved before these optimized protocols are implemented in routine screening. Keywords: Low-Dose CT (LDCT), Optimization, Lung Cancer Screening, Radiation Dose, Image Quality, CT Tissue Equivalent Phantom.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=18; title_english_function_words=4; title_english_share=0.2222; title_reads=english; abstract_words=262; abstract_english_function_words=73; abstract_english_share=0.2786; abstract_reads=english; language_check=metadata_listed