Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Ultra-low-dose computed tomography for attenuation correction of cadmium-zinc-telluride single photon emission computed tomography myocardial perfusion imaging
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- Crossref, OpenAlex
- Free full text
- Not looked for in this run
Abstract
BACKGROUND: The applicability of ultra-low-dose computed tomography (CT) for attenuation correction (AC) of single-photon-emission computed tomography myocardial perfusion imaging (SPECT-MPI) remains elusive. METHODS AND RESULTS: One-hundred patients underwent one-day 99mTc-tetrofosmin stress-rest MPI and non-contrast enhanced cardiac CT with 120, 80, and 70 kilovolt peak (kVp) tube voltage and tube current of 200 milliamperes for creation of AC maps. Normalized percent myocardial uptake from SPECT-MPI using 80 kVp scans for AC showed excellent correlation vs AC from 120 kVp scans for stress [intraclass correlation (ICC) = 0.988, 95% CI = 0.986-0.989, P < .001] and rest (ICC = 0.985, 95% CI = 0.983-0.987, P < .001) with narrow Bland-Altman limits of agreement (BA-LA) (- 5.3% to 4.5% and - 5.4% to 4.4%, respectively) and minimal bias (- 0.4% and - 0.5%, respectively). Correlation of AC SPECT-MPI based on 70 vs 120 kVp scans was excellent for stress (ICC = 0.988, 95% CI = 0.986-0.989, P < .001) and rest (ICC = 0.986, 95% CI = 0.984-0.987, P < .001) with narrow BA-LA (- 5.3% to 4.4% and - 5.2% to 4.5%, respectively) and small bias (- 0.4% and - 0.3%, respectively). Mean effective radiation dose for the 120, 80 and 70 kVp scans were 0.58 ± 0.07, 0.19 ± 0.02, and 0.12 ± 0.01 mSv, respectively. CONCLUSIONS: Attenuation maps for MPI obtained from ultra-low radiation dose CT scans are interchangeable with attenuation maps from standard-dose CT while offering a substantial reduction in radiation dose exposure.
From PubMed.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=20; title_english_function_words=2; title_english_share=0.1000; title_reads=english; abstract_words=193; abstract_english_function_words=48; abstract_english_share=0.2487; abstract_reads=english; language_check=metadata_listed