Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Clinical feasibility of fully automated three-dimensional liver segmentation in low-dose chest computed tomography (CT) for assessing hepatic steatosis: an alternative to abdominal CT

S. Han; I. Joo; J. Park; S.K. Jeon; S.H. Yoon (2025). Clinical Radiology

DOI 10.1016/j.crad.2025.107079

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

AIM: The aim of this study was to evaluate the clinical feasibility of fully automated three-dimensional (3D) liver segmentation using low-dose chest computed tomography (LDCT) as an alternative to nonenhanced abdominal computed tomography (AbCT) for the assessment of hepatic steatosis (HS). MATERIALS AND METHODS: We retrospectively analysed 642 adults with both LDCT and nonenhanced AbCT at 120 kVp. Using a fully automated 3D segmentation algorithm; the mean volumetric computed tomography (CT) attenuation of the liver was measured using both LDCT (for the included liver volume) and AbCT. The LDCT- and AbCT-measured liver Hounsfield unit (HU) values were compared using the intraclass correlation coefficient (ICC) and linear regression analysis. The correlation between LDCT- and AbCT-estimated HS grades using predefined cut-offs of 57 HU for mild HS and 40 HU for moderate HS was assessed using kappa statistics. Diagnostic performances of LDCT-measured HU were assessed using receiver operating characteristic (ROC) curve analysis with AbCT-based HS grades as a reference. RESULTS: LDCT-measured liver HU showed excellent absolute agreement (ICC = 0.961, P<0.001) and a significant correlation (adjusted R2 = 0.857) with AbCT-measured values. Subjects were categorised as normal/mild/moderate-to-severe HS in 322/283/37 by LDCT and 321/283/38 by AbCT, respectively, with significant correlations found for detecting HS (unweighted-κ = 0.741) and for grading HS (weighted-κ = 0.755). When using AbCT as a reference, the LDCT-measured liver HU resulted in an area under the ROC curve of 0.925 for mild HS and 0.986 for moderate HS. CONCLUSION: The LDCT-derived volumetric liver HU and HS grading based on these measurements strongly aligned with AbCT-based evaluation, indicating the potential of LDCT as an AbCT alternative in HS screening.

From PubMed.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=25; title_english_function_words=5; title_english_share=0.2000; title_reads=english; abstract_words=272; abstract_english_function_words=81; abstract_english_share=0.2978; abstract_reads=english; language_check=metadata_listed