Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Evaluation of a novel lower radiation computed tomography protocol for assessment of tunnel position post anterior cruciate ligament reconstruction

Varun Vasudeva; Stephen Key; Alfred Phillips; Steven Kahane; Joseph Stevens; Christopher J Wall; Price Gallie (2020). BMC Medical Imaging

DOI 10.1186/s12880-020-00480-5

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

BACKGROUND: Anterior cruciate ligament (ACL) reconstruction is a common orthopaedic procedure. We developed a novel, low dose computed tomography (LDCT) protocol to assess tunnel position post-operatively. The effective radiation dose of this protocol is < 0.5millisieverts (mSv), which is significantly less than the 2 mSv dose for a conventional CT protocol. The aim of this study was to assess the accuracy of the LDCT protocol for determining tunnel position. METHODS: Twenty-six patients who underwent primary ACL reconstruction were included in the study. A LDCT scan was performed 6 weeks post-operatively. Femoral and tibial tunnel positions were measured on three dimensional (3D) reconstructions using previously validated techniques. Measurements were performed independently by three observers at two time points, 4 weeks apart. RESULTS: There was excellent intra- and inter-rater reliability for all measurements using the images obtained from the LDCT protocol. Intra-class correlation coefficient (ICC) values were > 0.9 for all measurements. CONCLUSIONS: The LDCT protocol described in this study accurately demonstrates femoral and tibial tunnels post ACL reconstruction, while exposing the patient to a quarter of the radiation dose of a conventional CT. This protocol could be used by orthopaedic surgeons for routine post-operative imaging, in place of plain film radiographs.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=19; title_english_function_words=4; title_english_share=0.2105; title_reads=english; abstract_words=200; abstract_english_function_words=65; abstract_english_share=0.3250; abstract_reads=english; language_check=metadata_listed