Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

CaGAN: A Cycle-Consistent Generative Adversarial Network With Attention for Low-Dose CT Imaging

Zhiyuan Huang; Zixiang Chen; Qiyang Zhang; Guotao Quan; Min Ji; Chengjin Zhang; Yongfeng Yang; Xin Liu; Dong Liang; Hairong Zheng; Zhanli Hu (2020). IEEE Transactions on Computational Imaging

DOI 10.1109/tci.2020.3012928

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Although lowering X-ray radiation helps reduce the risk of cancer in patients, low-dose computed tomography (LDCT) technology usually leads to poor image quality, such as amplified mottle noise and streak artifacts, which severely impact the diagnostic results. To improve diagnostic performance, we propose an algorithm based on a cycle-consistent generative adversarial network (CycleGAN) to suppress noise and reduce artifacts. In addition, we include attention mechanisms in the proposed network to expand the receptive field and capture richer contextual dependencies. Unlike traditional methods that manually match similar local blocks, our proposed method can autonomously learn the relationship between local features and their global dependencies. Specifically, two different types of attention modules (criss-cross self-attention (CCSA) and channel attention (CA)) are adopted to enhance feature interdependencies in the spatial and channel dimensions separately. Because of the CCSA mechanism, noise and artifacts can be restored using cues from all local feature locations; the CA mechanism adaptively reassigns the weights of each feature map. Furthermore, we also performed a diagnostic quality assessment of the results and ablation studies of the loss functions and the structural modules, which showed the validity of our proposed method. Extensive experiments show that our proposed method achieves better metrics and visual effects than state-of-the-art methods.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=14; title_english_function_words=3; title_english_share=0.2143; title_reads=english; abstract_words=213; abstract_english_function_words=67; abstract_english_share=0.3146; abstract_reads=english; language_check=metadata_listed