Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Low-dose Computed Tomography Scans for Postoperative Evaluation of Craniomaxillofacial Fractures: A Pilot Clinical Study

Adekunle I. Elegbede; Silviu C. Diaconu; David Dreizin; Ryan Dunlow; Selim G. Gebran; Ledibabari Mildred Ngaage; Emmanuel C. Obusez; Colton H. L. McNichols; Yvonne M. Rasko; Fan Liang; Michael P. Grant; Arthur J. Nam (2019). Plastic & Reconstructive Surgery Global Open

DOI 10.1097/01.gox.0000585020.23040.0f

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

BACKGROUND: It is common practice for surgeons to obtain a craniomaxillofacial computed tomography (CT) scan to evaluate fracture reduction and implant positioning following the surgical reconstruction of facial fractures. CT scans contribute to the potential stochastic health risk from cumulative radiation exposure. This study was aimed at testing the hypothesis that an ultralow dose CT protocol is effective for postoperative diagnostic evaluation of craniomaxillofacial fractures. METHODS: This observational study was conducted at a level 1 trauma center. We included patients for whom CT was indicated for postoperative evaluation of their reconstructed craniomaxillofacial fractures. Postoperative craniomaxillofacial CT was performed utilizing an ultralow-dose protocol (0.1 mSv), rather than the standard protocol (3.6 mSv). A craniomaxillofacial surgeon and a radiologist independently interpreted the images to determine whether the image quality was adequate for assessing fracture reduction and implant position. It was decided a priori that any inadequate ultralow-dose CT would require repeat scanning utilizing the standard protocol. The primary endpoint was the need for repeat CT, as determined by the surgeon or radiologist. RESULTS: Twenty patients met inclusion criteria. Mean radiation dose (total dose-length product) from the ultralow-dose protocol was 71 versus 532 mGycm for the preoperative CTs which were performed using the regular protocol (P < 0.001). All 20 patients’ ultralow-dose postoperative CTs were determined to be satisfactory. No patient required repeat CT secondary to poor image quality of the ultralow-dose scans. CONCLUSIONS: Our ultralow-dose CT protocol which delivers 7.5-fold less radiation than the standard protocol seems adequate for routine postoperative evaluation of reconstructed facial fractures. Larger prospective studies may be warranted.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=15; title_english_function_words=3; title_english_share=0.2000; title_reads=english; abstract_words=259; abstract_english_function_words=83; abstract_english_share=0.3205; abstract_reads=english; language_check=metadata_listed