Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Physician Preference Between Low-Dose Computed Tomography With a Sinogram-Affirmed Iterative Reconstruction Algorithm and Routine-Dose Computed Tomography With Filtered Back Projection in Abdominopelvic Imaging

Andrew D. Hardie; Sameer V. Tipnis; William J. Rieter; Michael S. Rissing; Carlo N. De Cecco (2013). Journal of Computer Assisted Tomography

DOI 10.1097/rct.0000000000000024

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref, OpenAlex
Free full text
Not looked for in this run

Abstract

OBJECTIVE: The aim of this study was to directly compare the preference between low-dose sinogram-affirmed iterative reconstruction (SAFIRE) and routine filtered back projection (FBP) abdominopelvic computed tomography (CT). METHODS: A retrospective review identified 41 subjects who had undergone 2 different CT examinations at different times (a CT with reduced radiation dose SAFIRE and also a CT with routine-dose FBP). Radiation dose, patient size, and image noise were recorded. Two independent readers assessed the paired CT studies for preference in image quality in regard to 3 clinically relevant diagnostic endpoints (bowel pathology, biliary pathology, and general purpose). RESULTS: Radiation dose was significantly lower for SAFIRE (mean, 7.6 mGy; range, 4.1-15.4 mGy) than FBP (12.9 mGy; 6.7-31.6 mGy) (P < 0.001). Sinogram-affirmed iterative reconstruction was preferred for the general purpose and bowel evaluations, particularly when the level of radiation dose reduction was less than 33%. The preference for interpretation of the biliary system was equivocal, especially when the level of radiation reduction was increased greater than 33%. Filtered back projection was preferred when SAFIRE had a radiation reduction from FBP of greater than 50%. CONCLUSIONS: For abdominopelvic CT, low-dose CT with SAFIRE may produce preferred image quality over FBP up to levels of 50% dose reduction.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=26; title_english_function_words=6; title_english_share=0.2308; title_reads=english; abstract_words=196; abstract_english_function_words=61; abstract_english_share=0.3112; abstract_reads=english; language_check=metadata_listed