Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
SIGNIFICANCE OF LOW DOSE COMPUTED TOMOGRAPHY SCAN OF PARANASAL SINUSES
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- Crossref, OpenAlex
- Free full text
- Not looked for in this run
Abstract
Computed tomography is higher modality of X-Ray imaging.In computed tomography the dose are generally expressed in CTDIvol, DLP.The purpose of this study is to reduce the exposure dose to the CT PNS patients by adjusting tube current manually without affecting the diagnostic images.The aim of this study is to reduce the effective dose to the CT PNS patients by following the ALRA principle.Objective of this study is to rule out whether the manual tube current adjustment affects the reduction of effective dose of patient.Another objective is to rule out whether the reduction of the dose affects the image quality.This retrospective cohort study was done at the department of Radiodiagnosis of Maharishi Markendeshwar Institute of Medical Sciences and Research, Mullana, Ambala, Haryana.The study was carried out in 40 patients including 20 of each protocol.Tube current is reduced manually from 251mAs to 100mAs by keeping the voltage 120 kV at constant in the NCCT PNS patients.CTDIvol and DLP doses were obtained from the examination summery of both the protocols (Standard dose and Low dose).DLP is converted to effective dose by multiplying the DLP with the conversion coefficient for the facial skull that is 0.0023 mSv/ mGy X cm.Mean value of CTDIvol and DLP were respectively 32.39 mGy and 683.26 mGy X cm for STD PNS, 12.985 mGy and 232.68 mGy X cm for LD PNS.For STD PNS the mean effective dose was 1.55 mSv and for LD PNS the effective dose dramatically reduced to 0.503 mSv.The mean rating point for both the protocols was 5 and 4.8 respectively for STD and LD PNS.The study shows positive results and proves that we can reduce the radiation dose to the patient in CT PNS by reducing the tube current manually without affecting the image quality.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Unclear (checked by an automatic rule)What the rule found: language_in: language=; title_words=10; title_english_function_words=2; title_english_share=0.2000; title_reads=english; abstract_words=294; abstract_english_function_words=117; abstract_english_share=0.3980; abstract_reads=english; language_check=metadata_missing