Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Computer-aided Detection of Peripheral Lung Cancers Missed at CT: ROC Analyses without and with Localization
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
PURPOSE: To retrospectively evaluate whether a difference-image computer-aided detection (CAD) scheme can help radiologists detect peripheral lung cancers missed at low-dose computed tomography (CT). MATERIALS AND METHODS: Institutional review board approval and informed patient and observer consent were obtained. Seventeen patients (eight men and nine women; mean age, 60 years) with a missed peripheral lung cancer and 10 control subjects (five men and five women; mean age, 63 years) without cancer at low-dose CT were included in an observer study. Fourteen radiologists were divided into two groups on the basis of different image display formats: Six radiologists (group 1) reviewed CT scans with a multiformat display, and eight radiologists (group 2) reviewed images with a "stacked" cine-mode display. The radiologists, first without and then with the CAD scheme, indicated their confidence level regarding the presence (or absence) of cancer and the most likely position of a lesion on each CT scan. Receiver operating characteristic (ROC) curves were calculated without and with localization to evaluate the observers' performance. RESULTS: With the CAD scheme, the average area under the ROC curve improved from 0.763 to 0.854 for all radiologists (P = .002), from 0.757 to 0.862 for group 1 (P = .04), and from 0.768 to 0.848 for group 2 (P = .01). The average sensitivity in the detection of 17 cancers improved from 52% (124 of 238 observations) to 68% (163 of 238 observations) for all radiologists (P < .001), from 49% (50 of 102 observations) to 71% (72 of 102 observations) for group 1 (P = .02), and from 54% (74 of 136 observations) to 67% (91 of 136 observations) for group 2 (P = .006). The localization ROC curve also improved. CONCLUSION: Lung cancers missed at low-dose CT were very difficult to detect, even in an observer study. The use of CAD, however, can improve radiologists' performance in the detection of these subtle cancers.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=16; title_english_function_words=5; title_english_share=0.3125; title_reads=english; abstract_words=275; abstract_english_function_words=105; abstract_english_share=0.3818; abstract_reads=english; language_check=metadata_listed