Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
A Quantitative Study Comparing Ankle X-ray Imaging and Low-dose Computed Tomography (CT) Scans for Post-operative Evaluation of Total Ankle Replacements (TARs)
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
Background: A total ankle replacement (TAR) is a surgical procedure in which damaged bone and cartilage are replaced with a prosthetic implant. New Zealand has seen an increase in TAR surgeries, yet complication rates remain relatively high. Ankle X-ray imaging remains the standard post operative imaging modality, but its two-dimensional nature limits assessment accuracy. Low-dose computed tomography (CT) with metal artifact reduction (MAR) algorithms could be a potential alternative post-operative imaging modality, offering three-dimensional visualisation and diagnostic confidence, although the effective dose must be considered. Limited research has compared the performance and effective doses of these post-operative imaging approaches. This study addresses this gap by comparing ankle X-ray imaging and low-dose CT for routine TAR follow-up. Aims: To determine whether low-dose ankle CT scans provide superior post-operative evaluation of TARs compared with ankle X-ray imaging, while considering associated effective doses. Methods: Thirty participants who underwent a TAR surgery at a Dunedin Hospital between August 2024 and February 2025 were recruited. Each participant had weight-bearing ankle X-ray imaging and a low-dose CT scan six weeks post-operatively. Prosthesis alignment was measured using an adapted Wood & Deakin criteria (angles A, B, C). Radiation metrics included dose area product (DAP) for the ankle X-ray imaging and CT dose index volume (CTDIvol) for the CT scans. Wilcoxon signed-rank tests assessed differences between the modalities. Results: Angles ‘A’ and ‘B’ showed no significant difference between CT and the ankle X-ray imaging (p=0.47, p=0.76), while angle ‘C’ differed slightly (p=0.013). One post-operative complication (3%) was detected. Twenty percent of the ankle X-ray imaging had suboptimal positioning, and CT scans were affected by metal artifacts in 13.3% of cases. The mean CTDIvol was 1.38 milligray (mGy); lateral X-ray projections had higher DAPs than AP projections (p<0.05). Repeated X-ray projections increased dose variability. Conclusion: Both modalities provided comparable early alignment assessments. CT offers enhanced consistency and 3D visualisation, but was limited by artifacts and cost. Ankle X-ray imaging remains a practical first-line method for TAR imaging, although accuracy depends on proper positioning. Early imaging detects few complications, suggesting that timelines should align with the onset of later complications.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=24; title_english_function_words=4; title_english_share=0.1667; title_reads=english; abstract_words=369; abstract_english_function_words=96; abstract_english_share=0.2602; abstract_reads=english; language_check=metadata_listed