Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
BIONOTE e-nose technology may reduce false positives in lung cancer screening programmes
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
OBJECTIVES: Breath composition may be suggestive of different conditions. E-nose technology has been used to profile volatile organic compounds (VOCs) pattern in the breath of patients compared with that of healthy individuals. BIOsensor-based multisensorial system for mimicking NOse, Tongue and Eyes (BIONOTE) technology differs from Cyranose® based on a set of separate transduction features. On the basis of our previously published experience, we investigated the discriminating ability of BIONOTE in a high-risk population enrolled in a lung cancer screening programme. METHODS: One hundred individuals were selected for BIONOTE based on the attribution to the high-risk category (i.e. age, smoking status, chronic obstructive pulmonary disease status) of the University Campus Bio-Medico lung screening programme. We used a measure chain consisting of (i) a device named Pneumopipe (EU patent: EP2641537 (A1):2013-09-25) able to catch exhaled breath by an individual normally breathing into it and collect the exhalate onto an adsorbing cartridge; (ii) an apparatus for thermal desorption of the cartridge into the sensors chamber and (iii) a gas sensor array which is part of a sensorial platform named BIONOTE for the VOCs mixture analysis. Partial least square (PLS) has been used to build up the model, with Leave-One-Out cross-validation criterion. Each breath fingerprint analysis costs €10. RESULTS: The overall sensitivity and specificity were 86 and 95%, respectively, delineating a substantial difference between patients and healthy individuals. CONCLUSIONS: Our preliminary data show that BIONOTE technology may be used to reduce false-positive rates resulting from lung cancer screening with low-dose computed tomography in a cost-effective fashion. The model will be tested on a larger number of patients to confirm the reliability of these results.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=13; title_english_function_words=2; title_english_share=0.1538; title_reads=english; abstract_words=279; abstract_english_function_words=95; abstract_english_share=0.3405; abstract_reads=english; language_check=metadata_listed