Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Application of Dual-source Low-dose Computed Tomography in Common Chest Inspection
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
Objective To discuss the application of dual-source low-dose computed tomography in common chest inspection.Methods A total of 875 consecutive patients treated in our hospital betwwen Auguest 2011 and December 2012 were orderly divided into seven groups.From group one to group seven,the tube current of each group was ordinal 110,105,100,95,90,85,and 80 mAs.The standard deviation of mediastinal window image before sternum air,signal to noise ratio of pulmonary artery branch plane pulmonary artery,signal to noise ratio of aorta descendens,noise ratio contrast between pulmonary artery and erector spinae,noise ratio contrast between aorta descendens and erector spinae,score of mediastinal window image and pulmonary window image subjective diagnosis and the indexes of radiation dose,including CT dose index(CTDI),dose length product(DLP),and effective dose(ED) were measured,calculated and assessed respectively on CT images of mediastinal window and lung window in all the seven groups.Results The standard deviation of mediastinal window images,signal to noise ratio of pulmonary artery branch plane pulmonary artery,signal to noise ratio of aorta descendens,score of subjective diagnosis and the indexes of radiation dose,including CTDI,DLP,and ED of CT images were significantly different from each other among the seven groups(P0.05),while noise ratio contrast between pulmonary artery and erector spinae and between aorta descendens and erector spinae were not statistically significant(P0.05).The signal to noise ratio,radiation dose and score of subjective diagnosis of group seven were the lowest of all groups,and transverse stripe artifacts appeared on the humeral back in part of the images,which disturbed apex of lung lesions and made it difficult to provide enough diagnostic information.Conclusions The method of decreasing tube current gradually in common chest CT inspection can ensure that radiologists are able to adapt to low-dose image bit by bit,and this method can be popularized to all kinds of CT facilities we own currently.The images with 85 mAs as tube current in common chest inspection with dual-source CT can fulfill the need of diagnosis,and the radiation dose of patients is apparently lower than the conventional scan.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=12; title_english_function_words=2; title_english_share=0.1667; title_reads=english; abstract_words=352; abstract_english_function_words=119; abstract_english_share=0.3381; abstract_reads=english; language_check=metadata_listed