Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

A plasma 9-microRNA signature for lung cancer early detection: a multicenter analysis

Elisa Dama; Tommaso Colangelo; Roberto Cuttano; Rafał Dziadziuszko; Thomas Dandekar; Piotr Widłak; Witold Rzyman; Giulia Veronesi; Fabrizio Bianchi (2025). Biomarker Research

DOI 10.1186/s40364-025-00787-x

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Lung cancer remains the leading cause of cancer-related deaths worldwide. Low-dose computed tomography (LD-CT) screening, combined with effective minimally invasive molecular testing such circulating microRNA, has the potential to reduce the burden of lung cancer. However, their clinical application requires further validation, including studies across diverse patient cohorts from different countries. In this study, we propose a signature of 9 circulating miRNAs derived from a robust multi-platform workflow with a multi-center design, for a total of 276 lung cancer and 451 non-cancer controls, based on the data from two European LD-CT screening cohorts (Poland and Italy). The classification performance of the signature was stable in the two screening cohorts, with AUC=0.78 (SE, 76%; SP, 67%; ACC=70%), and AUC=0.75 (SE, 82%; SP, 68%; ACC=71%) in the Polish and Italian cohorts, respectively. The diagnostic accuracy of the signature was remarkably independent of age, gender, smoking (status and intensity), nodule size, and density. Additionally, the signature demonstrated strong performance in detecting stage I lung cancer, with AUC=0.76 (95%CI: 0.68-0.84), and 0.69 (95%CI: 0.49-0.89) in the Polish and Italian cohorts respectively, with a prediction ability of 63-73%. The signature's ability to discriminate benign nodules was satisfactory, with AUC=0.71 (95%CI: 0.58-0.84). The proposed panel of 9 circulating miRNAs provides a robust and precise diagnostic tool to substantially advance the effectiveness of the LD-CT screening program.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=12; title_english_function_words=3; title_english_share=0.2500; title_reads=english; abstract_words=216; abstract_english_function_words=69; abstract_english_share=0.3194; abstract_reads=english; language_check=metadata_listed