Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
An Ordinal Radiomic Model to Predict the Differentiation Grade of Invasive Non-Mucinous Pulmonary Adenocarcinoma Based on Low-Dose Computed Tomography in Lung Cancer Screening
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
OBJECTIVES: To construct a radiomic model of low-dose CT (LDCT) to predict the differentiation grade of invasive non-mucinous pulmonary adenocarcinoma (IPA) and compare its diagnostic performance with quantitative-semantic model and radiologists. METHODS: A total of 682 pulmonary nodules were divided into the primary cohort (181 grade 1; 254 grade 2; 64 grade 3) and validation cohort (69 grade 1; 99 grade 2; 15 grade 3) according to scanners. The radiomic and quantitative-semantic models were built using ordinal logistic regression. The diagnostic performance of the models and radiologists was assessed by the area under the curve (AUC) of the receiver operating characteristic curve and accuracy. RESULTS: The radiomic model demonstrated excellent diagnostic performance in the validation cohort (AUC, 0.900 (95%CI: 0.847-0.939) for Grade 1 vs. Grade 2/Grade 3; AUC, 0.929 (95%CI: 0.882-0.962) for Grade 1/Grade 2 vs. Grade 3; accuracy, 0.803 (95%CI: 0.737-0.857)). No significant difference in diagnostic performance was found between the radiomic model and radiological expert (AUC, 0.840 (95%CI: 0.779-0.890) for Grade 1 vs. Grade 2/Grade 3, p = 0.130; AUC, 0.852 (95%CI: 0.793-0.900) for Grade 1/Grade 2 vs. Grade 3, p = 0.170; accuracy, 0.743 (95%CI: 0.673-0.804), p = 0.079), but the radiomic model outperformed the quantitative-semantic model and inexperienced radiologists (all p < 0.05). CONCLUSIONS: The radiomic model of LDCT can be used to predict the differentiation grade of IPA in lung cancer screening, and its diagnostic performance is comparable to that of radiological expert. KEY POINTS: • Early identifying the novel differentiation grade of invasive non-mucinous pulmonary adenocarcinoma may provide guidance for further surveillance, surgical strategy, or more adjuvant treatment. • The diagnostic performance of the radiomic model is comparable to that of a radiological expert and superior to that of the quantitative-semantic model and inexperienced radiologists. • The radiomic model of low-dose CT can be used to predict the differentiation grade of invasive non-mucinous pulmonary adenocarcinoma in lung cancer screening.
From PubMed.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=25; title_english_function_words=6; title_english_share=0.2400; title_reads=english; abstract_words=280; abstract_english_function_words=91; abstract_english_share=0.3250; abstract_reads=english; language_check=metadata_listed