Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

A systematic review and meta-analysis of randomized controlled trials comparing low-dose versus standard-dose computed tomography-guided lung biopsy

Teng Li; Guanghui Xu; Wenjun Li; Yun Liu (2024). Journal of Cardiothoracic Surgery

DOI 10.1186/s13019-024-02792-x

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref, OpenAlex
Free full text
Not looked for in this run

Abstract

Abstract Background Despite the existence of several Randomized Controlled Trials (RCTs) investigating Low-Dose Computed Tomography (LDCT) as a guide in lung biopsies, conclusive findings remain elusive. To address this contention, we conducted a systematic review and meta-analysis to evaluate the efficacy and safety of LDCT-guided lung biopsies. Methods A comprehensive search across major databases identified RCTs comparing the effectiveness of LDCT-guided with Standard-Dose Computed Tomography (SDCT)-guided lung biopsies. Subsequently, we utilized a random-effects model meta-analysis to assess diagnostic accuracy, radiation dose, operation duration, and clinical complications associated with these procedures. Results Out of 292 scrutinized studies, six RCTs representing 922 patients were included in the final analysis. Results indicated the differences between the LDCT and SDCT groups were not different with statistical significance in terms of diagnostic accuracy rates (Intent-to-Treat (ITT) populations: Relative Risk (RR) 1.01, 95% Confidence interval [CI] 0.97–1.06, p = 0.61; Per-Protocol (PP) populations: RR 1.01, 95% CI 0.98–1.04, p = 0.46), incidence of pneumothorax (RR 1.00, 95% CI 0.75–1.35, p = 0.98), incidence of hemoptysis (RR 0.95, 95% CI 0.63–1.43, p = 0.80), and operation duration (minutes) (Mean Differences [MD] -0.34, 95% CI -1.67-0.99, p = 0.61). Notably, LDCT group demonstrated a lower radiation dose (mGy·cm) with statistical significance (MD -188.62, 95% CI -273.90 to -103.34, p < 0.0001). Conclusions The use of LDCT in lung biopsy procedures demonstrated equivalent efficacy and safety to standard methods while notably reducing patient radiation exposure.

From Crossref.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=21; title_english_function_words=3; title_english_share=0.1429; title_reads=english; abstract_words=216; abstract_english_function_words=50; abstract_english_share=0.2315; abstract_reads=english; language_check=metadata_listed