Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Constructing a machine learning-based non-invasive liquid biopsy model for lung cancer detection via miRNA sequencing.

Chia‐Hsun Hsieh; Tsung-Ting Hsieh; Ko-Han Lee; Yu-Hsuen Tu; Po-Ya Chang; Eva Yi-Hsuan Wu; Yu-Chuan Chang; Yen‐Jung Lu (2024). Journal of Clinical Oncology

DOI 10.1200/jco.2024.42.16_suppl.e20014

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

e20014 Background: Lung cancer is a prevalent and fatal disease, ranking second among common cancers globally. Early detection and prompt treatment significantly improve survival rates for most cancers, including lung cancer. Presently, low-dose computed tomography (LDCT) is a widely accepted tool for early lung cancer screening. However, it exhibits a high false-positive rate of up to 95%, resulting in overdiagnosis and causing anxiety among patients awaiting diagnosis results. Therefore, investigating alternative effective interventions would provide physicians with additional tools for evaluating lung cancer and making informed decisions. This study employs the concept of liquid biopsy, utilizing next-generation sequencing (NGS) to gather miRNA profiles, aiming to construct a machine learning-driven model for the detection of lung cancer. Methods: We assembled case-control cohorts, comprising 74 lung cancer cases (stage 0-II: 66; III-IV: 8) and 74 age- and gender-matched healthy control subjects, recruited from Chang Gung Memorial Hospital in Linkuo, Taiwan. Plasma derived from whole blood was collected from each subject before any cancer surgery or treatment. Subsequently, we extracted miRNA from the plasma and constructed libraries using the QIAseq miRNA Library kit for miRNA sequencing conducted on the Illumina NextSeq550 platform. RNA-seq data analysis was performed on miRNA sequencing data using the QIAGEN RNA-seq Analysis Portal 5.0. The count per million base (CPM) derived from the quantification results was utilized for differential analysis and constructing the machine learning model. To assess the model's performance, we reserved 10% of the subjects for isolated testing, while the remaining 90% underwent 10-fold cross-validation (CV). Results: The final model, built using logistic regression with six significant differentially expressed miRNAs (fold change > = 2 and P-value < = 0.01), achieved optimal performance. The 10-fold CV demonstrated accuracy: 97.73%; sensitivity: 98.48%; specificity: 96.97%; positive predictive value: 97.01%; negative predictive value: 98.46%. In isolated testing, all 16 subjects, including 8 cases and 8 controls, were correctly identified. Conclusions: This study with 148 subjects showcases the potential of NGS and machine learning for early-stage lung cancer detection via liquid biopsy. However, the sample size is relatively small, lacking cross-site subjects. Therefore, an additional multi-center clinical trial is underway to gather more subjects, aiming for a deeper investigation and more concrete conclusions in the near future.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=17; title_english_function_words=2; title_english_share=0.1176; title_reads=english; abstract_words=358; abstract_english_function_words=95; abstract_english_share=0.2654; abstract_reads=english; language_check=metadata_listed