Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
FADFNet: A fine-tunable and adaptive decomposition-fusion network for cross-dataset low-dose CT and low-dose PET image reconstruction
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
Low-dose computed tomography (LDCT) and low-dose positron emission tomography (LDPET) are pivotal for minimizing radiation risks in clinical practice, yet they inherently suffer from noise-induced image degradation. Although deep learning has advanced low-dose reconstruction, existing methods often lack adaptability across heterogeneous datasets and modalities due to severe domain shifts and rigid model architectures. To address these challenges, we propose FADFNet, a Fine-tunable and Adaptive Decomposition-Fusion Network designed for robust cross-domain reconstruction. Predicated on a frequency-aware paradigm, the proposed framework incorporates a Wavelet Transform-based Decomposition Module to explicitly disentangle the input into low-frequency structural components and high-frequency textural details. These components are processed by dual-branch experts equipped with a Context-Aware Spatial-Channel Modulation mechanism, which leverages structural priors to guide precise texture recovery. Subsequently, a Frequency Domain-based Feature Pyramid Fusion Module progressively integrates multi-scale features via global spectral attention to ensure comprehensive information synthesis. Furthermore, we introduce a parameter-efficient fine-tuning strategy that facilitates lightweight adaptation to unseen scanner domains by exclusively updating the modulation and fusion modules while freezing the pre-trained backbone. Extensive experiments on four LDCT datasets and four LDPET scenarios demonstrate the superiority of FADFNet over state-of-the-art methods. Quantitative results reveal that FADFNet achieves optimal signal fidelity and perceptual quality with significantly reduced computational overhead compared to generative approaches. Blind clinical evaluations further confirm that our method yields reconstruction quality comparable to full-dose reference images, substantiating its potential for reliable deployment in diverse clinical environments. The source code is available at FADFNet.
From PubMed.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=21; title_english_function_words=4; title_english_share=0.1905; title_reads=english; abstract_words=265; abstract_english_function_words=63; abstract_english_share=0.2377; abstract_reads=english; language_check=metadata_listed