Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Standard Versus Low-Dose Computed Tomography for Assessment of Acetabular Fracture Reduction

Stephen Gibbs; John Carney; Mary Kate Erdman; Alexander Telis; Adam Keith Lee; Mark E. Fleming; Jackson Lee; Eric A. White; Geoffrey S. Marecek (2020). Journal of Orthopaedic Trauma

DOI 10.1097/bot.0000000000001778

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

OBJECTIVE: First, to assess the impact of varying computed tomography (CT) radiation dose on surgeon assessment of postfixation acetabular fracture reduction and malpositioned implants. Second, to quantify the accuracy of CT assessments compared with the experimentally set displacement in cadaver specimens. We hypothesized that a CT dose would not affect the assessments and that CT assessments would show a high concordance with known displacement. METHODS: We created posterior wall acetabular fractures in 8 fresh-frozen cadaver hips and reduced them with varying combinations of step and gap displacement. The insertion of an intra-articular screw was randomized. Each specimen had a CT with standard (120 kV), intermediate (100 kV), and low-dose (80 kV) protocols, with and without metal artifact reduction postprocessing. Reviewers quantified gap and step displacement, overall reduction, quality of the scan, and identified intra-articular implants. RESULTS: There were no significant differences between the CT dose protocols for assessment of gap, step, overall displacement, or the presence of intra-articular screws. Reviewers correctly categorized displacement as anatomic (0-1 mm), imperfect (2-3 mm), or poor (>3 mm) in 27.5%-57.5% of specimens. When the anatomic and imperfect categories were condensed into a single category, these scores improved to 52.5%-82.5%. Intra-articular screws were correctly identified in 56.3% of cases. Interobserver reliability was poor or moderate for all items. Reviewers rated the quality of most scans as "sufficient" (60.0%-72.5%); reviewers more frequently rated the low-dose CT as "inferior" (30.0%) and the standard dose CT as "excellent" (25%). CONCLUSION: A CT dose did not affect assessment of displacement, intra-articular screw penetration, or subjective rating of scan quality in the setting of a fixed posterior wall fracture.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=12; title_english_function_words=2; title_english_share=0.1667; title_reads=english; abstract_words=264; abstract_english_function_words=92; abstract_english_share=0.3485; abstract_reads=english; language_check=metadata_listed