Dose Optimization

Euclid Seeram (2022). Computed Tomography

DOI 10.1201/9781003132554-6

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

The use of computed tomography (CT) as a medical diagnostic imaging tool has increased in recent decades because of its technical advances in data acquisition speed and image reconstruction technology. The increased reliance on CT was accompanied by increased patient exposure to ionizing radiation, however, and concerns among radiologic professionals and the public regarding CT dose resulted in increasing attention to dose reduction. Optimization of the dose has become increasingly important since there are concerns relating to the biological effects of exposure to patients, and in particular. the pediatric patient. Optimization of the dose considers several related topics in order to provide a clear understanding of protection of the patient. These topics include biological effects of radiation, radiation protection philosophy, need for dose optimization in CT, CT dosimetry fundamentals, dose factors in CT and their relationships with image-quality parameters, dose optimization efforts, including research on dose optimization in CT, and finally, the role of the operator in dose optimization. This chapter will explore these topics. First, two major classes of effects, namely stochastic and deterministic effects, are reviewed briefly. Furthermore, the International Commission on Radiological Protection (ICRP) radiation protection principle of optimization is outlined in order to lay the foundation for the need to optimize the dose in CT. Second, CT dose metrics such as the computed tomography dose index, the dose-length product, the size-specific dose estimate, and finally, the effective dose. The chapter concludes with a discussion of a dose optimization checklist, research considerations, and the role of the radiographer in CT dose optimization.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=2; title_english_function_words=0; title_english_share=0.0000; title_reads=too_short; abstract_words=258; abstract_english_function_words=95; abstract_english_share=0.3682; abstract_reads=english; language_check=metadata_listed