Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Sub-solid nodule detectability in seven observers of seventy-nine clinical cases: comparison between ultra-low-dose chest digital tomosynthesis with iterative reconstruction and chest radiography by receiver-operating characteristics analysis

Yukihiro Nagatani; Masashi Takahashi; Mitsuru Ikeda; Norihisa Nitta; Katsunori Miyata; Jun Hanaoka; Yasutaka Nakano; Satoru Matsuo; Yuto Hamada; Akinaga Sonoda; Hideji Otani; Noritoshi Ushio; Shinichi Ohta; Yoko Murakami; Chiaki Kaneko; Akitoshi Inoue; Tetsuo Kida; Kiyoshi Murata (2018). European Journal of Radiology

DOI 10.1016/j.ejrad.2018.08.006

Exclude AI

Does not meet: The study reports outcomes related to mortality, survival, early detection, illness, or disability in screened populations.

Decided by
The AI (Claude Haiku 4.5)
Basis
Abstract
Found in
OpenAlex
Free full text
Not looked for: free full text is sought only for some studies

Abstract

PURPOSE: To compare sub-solid nodules detectability (SSND) between ultra-low-dose chest digital tomosynthesis (ULD-CDT) with/without iterative reconstruction (IR) and chest radiography (CR) by using low-dose computed tomography (LDCT) as the standard of reference (SOR). MATERIALS AND METHODS: Institutional Review Board approved this study and written informed consent was obtained. In a single visit, 79 subjects underwent ULD-CDT at 120 kV and 10 mA, CR and LDCT (effective dose: 0.171, 0.117 and 3.52 mSv, respectively). Sixty-three coronal images were reconstructed using CDT with/without IR. SOR as to SSN presence was determined based on LDCT images. Seven radiologists recorded SSN presence and locations by continuously-distributed rating. Receiver-operating characteristic (ROC) analysis was used to compare SSND of ULD-CDT with/without IR and CR, in total and subgroups classified by nodular longest diameter (LD) (> or < 9 mm) and mean CT attenuation value (CTAV) (> or < -600 Hounsfield of Unit (HU)). Detection sensitivity (DS) was compared among 4 groups classified by combination of the identical thresholds: nodular LD (9 mm) and mean CTAV (-600 HU) in each of ULD-CDT with/without IR and CR with Friedman and Wilcoxon signed rank test. RESULTS: SSND for total 105 SSNs as well as larger SSNs with nodular LD of 9 mm or more at ULD-CDT with IR was higher than either that at ULD-CDT without IR or CR, as the areas under the ROC curve were 0.66 ± 0.02, 0.59 ± 0.01 and 0.52 ± 0.01, respectively (p < 0.05). DS at ULD-CDT with IR was 69.5 ± 10.8% in groups with larger (LD > 9 mm) and more-attenuated (>-600 HU) SSNs, and higher than in the other 3 groups (p < 0.05). CONCLUSION: ULD-CDT with IR demonstrated better SSND than that without IR or CR, with increased DS for larger and more-attenuated SSNs compared with the remaining ones.

From PubMed.

The criteria

  • Include if: The study presents original human clinical data on low-dose computed tomography screening for lung cancer.
    Unclear AI
    From the abstract: In a single visit, 79 subjects underwent ULD-CDT at 120 kV and 10 mA, CR and LDCT (effective dose: 0.171, 0.117 and 3.52 mSv, respectively).
    From the abstract: SOR as to SSN presence was determined based on LDCT images.
    From the abstract: Seven radiologists recorded SSN presence and locations by continuously-distributed rating.
  • Include if: The study reports outcomes related to mortality, survival, early detection, illness, or disability in screened populations.
    Does not meet AI
    From the abstract: RESULTS: SSND for total 105 SSNs as well as larger SSNs with nodular LD of 9 mm or more at ULD-CDT with IR was higher than either that at ULD-CDT without IR or CR, as the areas under the ROC curve were 0.66 ± 0.02, 0.59 ± 0.01 and 0.52 ± 0.01, respectively (p < 0.05).
    From the abstract: DS at ULD-CDT with IR was 69.5 ± 10.8% in groups with larger (LD > 9 mm) and more-attenuated (>-600 HU) SSNs, and higher than in the other 3 groups (p < 0.05).
  • Exclude if: Abstracts or meeting presentations.
    Does not apply AI
    From the record details: Source: OpenAlex; Type: article; Venue: European Journal of Radiology; Date: 2018-08-17; Language: en; Host: doi.org; Abstract source: PubMed
  • Exclude if: Review articles or opinion pieces.
    Does not apply AI
    From the abstract: In a single visit, 79 subjects underwent ULD-CDT at 120 kV and 10 mA, CR and LDCT (effective dose: 0.171, 0.117 and 3.52 mSv, respectively).
    From the abstract: Seven radiologists recorded SSN presence and locations by continuously-distributed rating.
    From the abstract: Receiver-operating characteristic (ROC) analysis was used to compare SSND of ULD-CDT with/without IR and CR, in total and subgroups classified by nodular longest diameter (LD) (> or < 9 mm) and mean CT attenuation value (CTAV) (> or < -600 Hounsfield of Unit (HU)).
  • Exclude if: Animal studies or laboratory experiments.
    Does not apply AI
    From the abstract: In a single visit, 79 subjects underwent ULD-CDT at 120 kV and 10 mA, CR and LDCT (effective dose: 0.171, 0.117 and 3.52 mSv, respectively).
  • Exclude if: Studies on emphysema or asbestos exposure.
    Does not apply AI
    From the title: Sub-solid nodule detectability in seven observers of seventy-nine clinical cases: comparison between ultra-low-dose chest digital tomosynthesis with iterative reconstruction and chest radiography by receiver-operating characteristics analysis
    From the abstract: PURPOSE: To compare sub-solid nodules detectability (SSND) between ultra-low-dose chest digital tomosynthesis (ULD-CDT) with/without iterative reconstruction (IR) and chest radiography (CR) by using low-dose computed tomography (LDCT) as the standard of reference (SOR).
  • Exclude if: Cost-effectiveness analyses or economic evaluations.
    Does not apply AI
    From the abstract: Receiver-operating characteristic (ROC) analysis was used to compare SSND of ULD-CDT with/without IR and CR, in total and subgroups classified by nodular longest diameter (LD) (> or < 9 mm) and mean CT attenuation value (CTAV) (> or < -600 Hounsfield of Unit (HU)).
    From the abstract: Detection sensitivity (DS) was compared among 4 groups classified by combination of the identical thresholds: nodular LD (9 mm) and mean CTAV (-600 HU) in each of ULD-CDT with/without IR and CR with Friedman and Wilcoxon signed rank test.
  • Exclude if: Microsimulation or mechanistic modeling studies.
    Does not apply AI
    From the abstract: In a single visit, 79 subjects underwent ULD-CDT at 120 kV and 10 mA, CR and LDCT (effective dose: 0.171, 0.117 and 3.52 mSv, respectively).
    From the abstract: Seven radiologists recorded SSN presence and locations by continuously-distributed rating.
  • Exclude if: Studies with fewer than 10 cases.
    Does not apply AI
    From the abstract: In a single visit, 79 subjects underwent ULD-CDT at 120 kV and 10 mA, CR and LDCT (effective dose: 0.171, 0.117 and 3.52 mSv, respectively).
    From the abstract: RESULTS: SSND for total 105 SSNs as well as larger SSNs with nodular LD of 9 mm or more at ULD-CDT with IR was higher than either that at ULD-CDT without IR or CR, as the areas under the ROC curve were 0.66 ± 0.02, 0.59 ± 0.01 and 0.52 ± 0.01, respectively (p < 0.05).
  • Exclude if: Studies not involving human subjects.
    Does not apply AI
    From the abstract: MATERIALS AND METHODS: Institutional Review Board approved this study and written informed consent was obtained.
    From the abstract: In a single visit, 79 subjects underwent ULD-CDT at 120 kV and 10 mA, CR and LDCT (effective dose: 0.171, 0.117 and 3.52 mSv, respectively).
  • Exclude if: Non-English language publications.
    Does not apply AI
    From the record details: Source: OpenAlex; Type: article; Venue: European Journal of Radiology; Date: 2018-08-17; Language: en; Host: doi.org; Abstract source: PubMed
  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=31; title_english_function_words=6; title_english_share=0.1935; title_reads=english; abstract_words=285; abstract_english_function_words=100; abstract_english_share=0.3509; abstract_reads=english; language_check=metadata_listed

Each quote is copied word for word from the text the AI read, and checked against it by code.