Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Population-based research of pulmonary subsolid nodule CT screening and artificial intelligence application

Feng Yang; Jun Fan; Junyi Tianzhou; Fan Yang; Yun Li; Xianping Liu; Jianfeng Li; Guanchao Jiang; Jun Wang (2020). Chinese Journal of Thoracic and Cardiovaescular Surgery

DOI 10.3760/cma.j.cn112434-20191126-00420

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Objective To investigate the application of low-dose chest CT(LDCT) in the screening of pulmonary subsolid nodules in population and the application value of artificial intelligence. Methods People who received chest LDCT screening between January 2015 and December 2017 were included. A retrospective study was developed to analyze the enrolled population features , detection of pulmonary subsolid nodules and independent predictors of subsolid nodules , and to evaluate the accuracy of the artificial intelligence reading method. Results Result of three cross-sectional studies reveals that the detection rates of pulmonary subsolid nodules were 0.42%, 0.69% and 0.92% in three rounds. 726 cases who completed the three rounds of screening were included in the cohort study. The cohort population was predominantly male(83.2%), with a median age of 43 years, and nearly half of the subjects(47.0%) had a history of smoking. GEE revealed that the patient's family history of lung cancer(OR=8.753, 95%CI: 1.877-40.816, P=0.006) was an independent predictor of the detection of subsolid nodules. In the 110 kVp tube voltage group, AUC of AI model was 0.740, and AUC of the manual reading method was 0.721, no significant differences were observed(P=0.502); when the preseted cutoff value of AI model was 0.75, the NRI was -0.15, indicating the accuracy of AI model was inferior to manual method(P=0.006). In the 130 kVp tube voltage group, AUC of the model was 0.888, and AUC of the manual reading method was 0.756, no significant differences were observed(P=0.128); and the NRI was 0.19, indicating the accuracy of AI model was not inferior to manual method(P=0.123). Conclusion This population' s detection rates of pulmonary subsolid nodules were 0.42%-0.92%. Family history of lung cancer was an independent predictor of subsolid pulmonary nodules. The result of AI pulmonary nodule detection model could be a reference when the training set data parameters match the actual application parameters. Key words: Lung neoplasms; Cancer screening; Multidetector computed tomography; Subsolid nodule; Artificial intelligence

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=13; title_english_function_words=2; title_english_share=0.1538; title_reads=english; abstract_words=306; abstract_english_function_words=111; abstract_english_share=0.3627; abstract_reads=english; language_check=metadata_listed