Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Harnessing Native-Resolution 2D Embeddings for Lung Cancer Classification: A Feasibility Study with the RAD-DINO Self-supervised Foundation Model

Md.Enamul Hoq; Lawrence Tarbox; Donald Joseph Johann; Linda J. Larson‐Prior; Fred Prior (2025). Journal of Imaging Informatics in Medicine

DOI 10.1007/s10278-025-01748-4

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Low‑dose CT (LDCT) screening reduces lung cancer mortality but yields high false‑positive findings, motivating practical AI that aligns with slice‑based clinical review. We evaluate a label‑efficient 2D pipeline that uses frozen RAD‑DINO embeddings from native‑resolution axial slices and a lightweight multilayer perceptron for patient‑level risk estimation via mean aggregation and isotonic calibration. Using the NLST CT arm with outcomes defined over a 0-24‑month window, we construct a fixed patient‑level split (one CT per patient; no cross‑split leakage) and perform 25 repeated imbalanced test draws (~ 6% prevalence) to approximate screening conditions. At screening prevalence, RAD‑DINO + MLP achieves PR‑AUC = 0.705 (calibrated; raw 0.554) and ROC‑AUC = 0.817 (raw; 0.736 calibrated), with improved probability reliability following calibration; operating points are selected on validation and reported on test. For secondary ablations only, a near‑balanced cohort (N = 1984) yields accuracy 0.966, precision 0.974, recall 0.973, F1 0.973, and ROC‑AUC 0.912. Beyond classification, retrieval with triplet‑fine‑tuned embeddings attains Precision@5 = 0.853. Interpretability analyses show that cancer cases sustain higher top‑k slice scores and that directional SHAP concentrates on a small subset of high‑probability slices; label‑colored t‑SNE provides qualitative views of embedding structure. Limitations include single‑cohort evaluation, lack of Lung‑RADS labels in public NLST, and a CXR → CT pretraining shift; future work will pursue external validation and CT‑native self‑supervised continuation. Overall, frozen 2D foundation embeddings provide a strong, transparent, and computationally practical starting point for LDCT screening workflows under realistic prevalence.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=20; title_english_function_words=4; title_english_share=0.2000; title_reads=english; abstract_words=243; abstract_english_function_words=47; abstract_english_share=0.1934; abstract_reads=english; language_check=metadata_listed