Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Ultra-low-dose computed tomography of the paranasal sinuses: evaluating diagnostic adequacy for chronic rhinosinusitis

Peter Watson-Brown; Marita Prior; Stefanie Lovell; Andrew Groundwater; Pranter Brahmabhatt; Benjamin Keir; Linda Stewart; Anders Cervin; Abigail Walker; Bronte Moses (2026). Australian Journal of Otolaryngology

DOI 10.21037/ajo-2025-1-74

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Background: Computed tomography (CT) of the paranasal sinuses is a key diagnostic tool in the assessment of sinonasal disease, including chronic rhinosinusitis (CRS). CT exposes patients to ionising radiation affecting sensitive structures such as the optic lens and thyroid. Patients with CRS often undergo repeated imaging, increasing cumulative dose. Given the high intrinsic contrast of sinus anatomy, substantial reductions in CT radiation dose may be possible without compromising diagnostic quality. This pilot study aimed to investigate the diagnostic adequacy of an ultra-low-dose (ULD) CT protocol for the assessment of sinonasal mucosal disease, using conventional CT scanning equipment and CRS as the index condition. Methods: Eleven adult patients with CRS were prospectively enrolled at a tertiary hospital. Each underwent both standard-dose (SD) and ULD CT of the paranasal sinuses on a Siemens Biograph mCT Flow scanner. The ULD CT protocol used 80 kV, tube current 20 mAs, and iterative reconstruction. Four blinded reporters (two Ear, Nose and Throat surgeons, two radiologists) independently assessed image quality on a 5-point Likert scale and graded disease severity using the Lund-Mackay (LM) score. Clinically significant disagreement was defined as a difference in LM score >2. Inter-rater reliability was evaluated using intraclass correlation coefficients (ICC) with 95% confidence interval (CI) and agreement on presence/absence of sinusitis with Fleiss’s kappa. Radiation doses were quantified using volume CT dose index (CTDI vol ), dose length product (DLP), and organ-specific dose estimates. Results: All images were deemed diagnostic by all reporters. The ULD CT protocol reduced radiation dose by approximately 90% compared with SD CT. Mean CTDI vol and DLP were 0.87 mGy and 12.85±1.04 mGy.cm (range, 11–14.4 mGy.cm) for ULD CT versus 8.05±1.12 mGy (range, 6.7–9.9 mGy) and 126.54±22.04 mGy·cm (range, 91–165.8 mGy·cm) for SD CT. Absorbed dose to the optic lens was 0.8 mGy with ULD CT compared with 6.7–9.9 mGy for SD CT. Thyroid and effective dose were negligible with ULD CT. Inter-rater reliability for LM scoring was excellent [ICC 0.94, 95% confidence interval (CI): 0.86–0.98 for ULD CT; ICC 0.96, 95% CI: 0.89–0.99 for SD CT]. Agreement on presence or absence of sinusitis between ULD and SD CT was good to very good across reporters (κ=0.79–1.0). Conclusions: This pilot study suggests that an ULD CT protocol can provide adequate image quality for the detection and grading of sinonasal mucosal disease, with an approximate 90% reduction in radiation dose compared with SD CT. Although validation in large studies is required, these preliminary findings indicate that a ULD CT protocol may provide a feasible and accessible option for screening and monitoring CRS.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=15; title_english_function_words=3; title_english_share=0.2000; title_reads=english; abstract_words=416; abstract_english_function_words=118; abstract_english_share=0.2837; abstract_reads=english; language_check=metadata_listed