Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Deep Learning to Quantify Body Composition in Lung Cancer Screening–Eligible Individuals

Johannes Beat Fingerhut; Fabian Bernhard Pallasch; Matthias Jung; Moritz Palmowski; Luisa Junele; Marco Reisert; Fabian Bamberg; Jakob Weiss; Johannes Jahn (2026). JCO Clinical Cancer Informatics

DOI 10.1200/cci-26-00030

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

PURPOSE Most low-dose computed tomography (LDCT) scans in lung cancer (LC) screening are negative, yet contain prognostic information. We developed a fully automated 3D deep learning model for thoracic body composition (BC) quantification from LDCT and evaluated its prognostic value for overall and cause-specific mortality. MATERIALS AND METHODS Baseline and first follow-up LDCTs from the National Lung Screening Trial were analyzed. A 3D convolutional neural network was trained for full thoracic volumetric segmentation of subcutaneous adipose tissue (SAT) and skeletal muscle (SM) and extraction of attenuation values. BC metrics were categorized into sex-specific percentile groups (<20%, 20%-80%, >80%). Kaplan-Meier and Cox regression assessed the association between baseline BC/1-year BC changes and all-cause mortality (primary end point) and atherosclerotic cardiovascular disease (ASCVD) and LC mortality (secondary end points) adjusted for age, sex, ethnicity, BMI, smoking status, diabetes, hypertension, and history of stroke or heart disease. RESULTS Among 23,195 participants (mean age 61.4 ± 5 years; 41.5% women), 1,601 (6.9%) deaths occurred over 6.5 years. Low SM volume and density were independently associated with increased all-cause mortality (adjusted hazard ratio [aHR], 1.40 [95% CI, 1.25 to 1.57]; aHR, 1.80 [95% CI, 1.60 to 2.02]; both P < .001). Similar associations were found for low SAT volume, high SAT density, and low SM density with ASCVD and LC mortality. A >10% 1-year decline in SAT or SM measures further increased mortality risk, strongest for reduced SAT density (aHR, 2.13 [95% CI, 1.54 to 2.95]; P < .001). CONCLUSION Automated 3D thoracic BC quantification from LDCT enables opportunistic, artificial intelligence–driven risk stratification beyond traditional factors, supporting personalized prevention in high-risk populations.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=12; title_english_function_words=2; title_english_share=0.1667; title_reads=english; abstract_words=249; abstract_english_function_words=58; abstract_english_share=0.2329; abstract_reads=english; language_check=metadata_listed