Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

SAVER: Stochastic Adaptive Variance-Driven Exploration and Reconstruction for Low-Dose Computed Tomography

Shunta Nonaga; Koji Tabata; Junya Honda; Hiroyuki Kudo; Wataru Yashiro; Tamiki Komatsuzaki (2026). Springer Science and Business Media LLC

DOI 10.21203/rs.3.rs-9844210/v1

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref, OpenAlex
Free full text
Not looked for in this run

Abstract

Abstract Computed Tomography (CT) is indispensable in clinical diagnostics, yet minimizing radiation dose without compromising image quality remains a critical challenge. Conventional low-dose protocols often rely on fixed, uniform angular sampling, independent of the underlying structural complexity of organs of individual patients. We propose ''Stochastic Adaptive Variance-Driven Exploration and Reconstruction'' (SAVER), an adaptive data acquisition framework that selects projection angles in real-time based on the statistical variance of acquired data. Utilizing a Softmax-based stochastic scheduling scheme with simulated annealing, SAVER prioritizes directions with high structural information while maintaining necessary exploration. Numerical experiments across 8 diverse phantoms demonstrate that SAVER achieves consistently higher reconstruction fidelity than conventional random sampling, particularly for objects with high structural anisotropy. Furthermore, the proposed method exhibits robust performance under significant measurement noise. By dynamically reallocating radiation dose to the most informative projections, SAVER provides a mathematically-grounded approach to maximize diagnostic quality per unit of radiation dose, marking a shift toward sample-dependent, data-driven CT acquisition.

From Crossref.

The criteria

  • Include if: The document is in English.
    Unclear (checked by an automatic rule)

    What the rule found: language_in: language=; title_words=13; title_english_function_words=2; title_english_share=0.1538; title_reads=english; abstract_words=164; abstract_english_function_words=37; abstract_english_share=0.2256; abstract_reads=english; language_check=metadata_missing