Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

F-041BIONOTE E-NOSE TECHNOLOGY MAY REDUCE FALSE POSITIVES IN LUNG CANCER SCREENING PROGRAMMES

Raffaele Rocco; Raffaele Antonelli Incalzi; Giorgio Pennazza; Marco Santonico; Claudio Pedone; Chiara Vernile; Giuseppe Mangiameli; Antonello La Rocca; Giuseppe De Luca; Gaetano Rocco; Pierfilippo Crucitti (2015). Interactive Cardiovascular and Thoracic Surgery

DOI 10.1093/icvts/ivv204.41

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Objectives: Breath composition may be suggestive of different conditions. E-nose technology has been used to separate volatile organic compounds (VOCs) in the breaths of patients compared to the breaths of healthy individuals. Bionote technology differs from cyranose based on a set of separate transduction features (ie, working principles, sensing material, and, array composition). Based on our previously published experience, we investigated the discriminating ability of BIONOTE in a high-risk population enrolled in a lung cancer screening programme. Methods: Twenty-one individuals (7 diagnosed with lung cancer and 14 controls) were selected based on the allocation to the high risk category. We used a measure chain consisting of (i) a device named Pneumopipe [EU patent: EP2641537 (A1):2013-09-25] able to catch exhaled breath by an individual normally breathing into it and collect the exhalate onto an adsorbing cartridge; (ii) an apparatus for thermal desorption of the cartridge into the sensors chamber; and (iii) a gas sensor array which is part of a sensorial platform named BIONOTE for the VOCs mixture analysis. Partial least square (PLS) has been used to build up the model, with Leave-One-Out as a cross-validation criterion. Results: Sensitivity and specificity were both 100%, delineating a substantial difference between patients and healthy individuals. Each breath fingerprint analysis costs 10 Euros. Conclusions: Our preliminary data show that BIONOTE technology may be used to reduce false positive rates resulting from lung cancer screening with LDCT in a cost-effective fashion. The model will be tested on a larger number of patients to confirm the reliability of these results. Disclosure: No significant relationships.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=14; title_english_function_words=2; title_english_share=0.1429; title_reads=english; abstract_words=261; abstract_english_function_words=92; abstract_english_share=0.3525; abstract_reads=english; language_check=metadata_listed