Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

THE ACCURACY OF THE LOW DOSE NATIVE COMPUTED TOMOGRAPHY PROTOCOL IN PATIENTS WITH SUSPECTED ACUTE APPENDICITIS

Department of Radiology and Medical Imaging Sulaymaniyah Teaching Hospital, Kurdistan Region, Iraq.; Hezha Mohammed (2024). Journal of Sulaimani Medical College

DOI 10.17656/jsmc.10482

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref
Free full text
Not looked for in this run

Abstract

Background To determine the accuracy of native computed tomography (CT) without the oral, intravenous, or rectal administration of contrast material in confirming suspected acute appendicitis. Objectives the prospective study conducted within six months in Shar hospital in cases were admitted with the abdominal pain and suspicion of acute appendicitis, and determination of the acute appendicitis diagnosed by clinical manifestations, ultrasound to exclude other possible right iliac fossa pain and then native low dose CT scan of the pelvic was done to diagnose acute appendicitis and determine the accuracy of the method by comparing the results to the histopathological examinations postoperatively. Materials and Methods low dose native CT scan and abdominal USG were performed for each patient presented with acute symptoms. CT examination for acute abdominal pain were performed without using intravenous contrast media, no oral nor rectal contrast were used. Examinations were performed on the GE the Optima CT660 enables 128 slices per rotation. Patients were between age of 18-45yrs of age with the clinical suspicion of acute appendicitis with the exclusion criteria includes patients with the prior history of appendectomy, female patients with pregnancy test positive , also patients with gynecological problem like ectopic pregnancy, ovarian cysts ,and patients with other gastrointestinal problem like diverticulitis, inflammatory bowel disease, and cancer patients were excluded in the total of 100 patients assessed, and the clinical manifestations, laboratory findings, imaging findings, operation records and pathological findings were analyzed. Results There were 88 cases true-positive diagnoses, 7cases were have alternative diagnosis which were excluded by the native CT scan, two false-negative diagnoses, and two false-positive diagnoses, which yielded a sensitivity of 97.8%, a specificity of 77.8%, and an accuracy of 96%. Conclusion Non-enhanced helical CT is a highly accurate technique for diagnosing or excluding acute appendicitis. Developing experience with the technique and understanding the subtleties of interpretation can further improve diagnostic accuracy.

From Crossref.

The criteria

  • Include if: The document is in English.
    Unclear (checked by an automatic rule)

    What the rule found: language_in: language=; title_words=16; title_english_function_words=5; title_english_share=0.3125; title_reads=english; abstract_words=306; abstract_english_function_words=106; abstract_english_share=0.3464; abstract_reads=english; language_check=metadata_missing