Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Feasibility of AI as first reader in the 4-IN-THE-LUNG-RUN lung cancer screening trial: impact on negative-misclassifications and clinical referral rate

Anna N.H. Walstra; Harriet L Lancaster; Marjolein A. Heuvelmans; Carlijn M. van der Aalst; Juul Hubert; Dana Moldovanu; Sytse F. Oudkerk; Daiwei Han; Jan Willem Gratama; Mario Silva; Harry J. de Koning; Matthijs Oudkerk (2024). European Journal of Cancer

DOI 10.1016/j.ejca.2024.115214

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Background Lung cancer screening (LCS) with low-dose CT (LDCT) reduces lung-cancer-related mortality in high-risk individuals. AI can potentially reduce radiologist workload as first-read-filter by ruling-out negative cases. The feasibility of AI as first reader was evaluated in the European 4-IN-THE-LUNG-RUN (4ITLR) trial, comparing its negative-misclassifications (NMs) to those of radiologists and the impact on referral rates. Methods NMs were collected from 3678 baseline LDCTs of the 4ITLR-dataset. LDCTs were read independently by radiologists and dedicated AI software (AVIEW-LCS, v1.1.42.92, Coreline-Soft, Seoul, Korea). A case was designated as NM when nodules > 100 mm 3 were present and either radiologist or AI gave a negative-classification (only nodules <100 mm 3 or no nodules), with an expert-panel as reference standard. A distinction was made between an indeterminate (100–300mm 3 ), and positive (>300 mm 3 ) classification, warranting referral for clinical-workup. Overall, there were 102 referrals (2.8 %) at baseline. Results Of the 3678 baseline scans, 438 NMs (11.9 %) were identified (age individuals: 68 (IQR: 64–73) years, 241 men); 31 (0.8 %) by AI and 407 (11.1 %) by radiologists. Among the 31 AI-NMs, 3 were classified positive and 28 indeterminate. Among the 407 radiologist-NMs, 4 were classified positive, and 403 were indeterminate, of which 8 were classified positive after receiving a three-month follow-up CT. Radiologists, as first reader, would have led to 12/102 (11.8 %) missed referrals, higher than the 3/102 (2.9 %) of AI. Conclusion This study showed AI outperforms radiologists with significantly less NMs and therefore shows promise as first reader in a LCS program at baseline, by independently ruling-out negative cases without substantially increasing the risk of missed clinical referrals.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=24; title_english_function_words=8; title_english_share=0.3333; title_reads=english; abstract_words=255; abstract_english_function_words=89; abstract_english_share=0.3490; abstract_reads=english; language_check=metadata_listed