Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Performance of ultra-low-dose CT for the evaluation of coronary calcification: a direct comparison with coronary calcium score

V.V. Silveira de Souza; Felipe Soares Torres; Bruno Hochhegger; Guilherme Watte; Gabriel Sartori Pacini; Fernando Antonio Lucchese; B. Azambuja Gonçalves (2017). Clinical Radiology

DOI 10.1016/j.crad.2017.03.015

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

AIM: To evaluate the diagnostic performance of ultra-low-dose computed tomography (ULDCT) in comparison to standard coronary calcium score (CCS) acquisition for the evaluation of coronary artery calcification (CAC). MATERIALS AND METHODS: Standard CCS acquisition and ULDCT were performed in patients referred for coronary CT angiography for the evaluation of coronary artery disease. CAC in ULDCT was graded subjectively using a four-point scale (from 0, no calcification, to 3, severe calcification) for the complete study and for each individual coronary segment. The summation of all individual coronary segment scores generated an ULDCT total CAC score. ULDCT results were compared to standard Agatston score and sensitivity and specificity of ULDCT were calculated. RESULTS: CCS and ULDCT were performed in 74 patients, with a mean DLP of 77.7 mGy·cm (±12.1) and 9.3 mGy·cm (±0.6), respectively (p<0.001). Coronary calcification was detected in 47 patients (63.5%) in standard CCS acquisition (median Agatston score of 41; interquartile range [IQR]:0263), in comparison to 42 patients (56.8%) in ULDCT (p<0.001). The sensitivity and specificity of the ULDCT total CAC score ≥1 was 80.9% and 85.2%, respectively, with an accuracy of 82.4%. The area under the receiver operating characteristic curve for the presence of CAC was 0.87. CONCLUSION: ULDCT shows good sensitivity, specificity, and overall accuracy for the detection of coronary calcification with a markedly lower radiation dose in comparison to CCS. ULDCT is unlikely to miss coronary calcification in individuals with at least moderate calcium load (Agatston score >100).

From PubMed.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=19; title_english_function_words=6; title_english_share=0.3158; title_reads=english; abstract_words=228; abstract_english_function_words=79; abstract_english_share=0.3465; abstract_reads=english; language_check=metadata_listed