Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Low-dose Computed Tomography (CT) for the Diagnosis of Congenital Heart Disease in Children: A Meta-analysis

Lu Tian; Longlun Wang; Yong Qin; Jinhua Cai (2020). Current Medical Imaging Formerly Current Medical Imaging Reviews

DOI 10.2174/1573405616666200107110611

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref, OpenAlex
Free full text
Not looked for in this run

Abstract

Background: Low dose CT has become a promising examination method for the diagnosis of Congenital heart disease (CHD) in children because it has a low radiation dose, but it has not been widely accepted as an alternative to standard-dose CT in clinical applications due to concerns about image quality. Therefore, we suggest that the diagnostic accuracy, image quality, and radiation dose of low-dose CT for CHD in children should be fully explored through a metaanalysis of existing studies. Methods: A comprehensive search was performed to identify relevant English and Chinese articles (from inception to May 2019). All selected studies concerned the diagnosis of CHD in children using low-dose CT. The accuracy of low-dose CT was determined by calculating pooled estimates of sensitivity, specificity, diagnostic odds ratio, and likelihood ratio. Pooling was conducted using a bivariate generalized linear mixed model. Forest plots and summary receiver operating characteristic (SROC) curves were generated. Results: Ten studies, accounting for 577 patients, met the eligibility criteria. The pooled sensitivity and specificity were 0.95 (95% confidence interval (CI) 0.92-0.97) and 1.00 (95% CI 1.00- 1.00), respectively. The pooled diagnostic odds ratio, positive likelihood ratio, and negative likelihood ratio of low-dose CT were 12705.53 (95% CI 5065.00-31871.73), 671.29 (95% CI 264.77- 1701.97), and 0.05 (95% CI 0.03-0.08), respectively. Additionally, the area under the SROC curve was 1.00 (95% CI 0.99-1.00), suggesting that low-dose CT is an excellent diagnostic tool for CHD in children. Conclusion: Low-dose CT, especially with a prospective ECG-triggering mode, provides excellent imaging quality and high diagnostic accuracy for CHD in children.

From Crossref.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=17; title_english_function_words=5; title_english_share=0.2941; title_reads=english; abstract_words=243; abstract_english_function_words=79; abstract_english_share=0.3251; abstract_reads=english; language_check=metadata_listed