Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Positron emission tomography in the diagnostic work-up of screening-detected lung nodules

Giulia Veronesi; Laura Lavinia Travaini; Patrick Maisonneuve; Cristiano Rampinelli; Raffaella Bertolotti; Lorenzo Spaggiari; Massimo Bellomi; Giovanni Paganelli (2014). European Respiratory Journal

DOI 10.1183/09031936.00066514

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Low-dose computed tomography (CT) screening for lung cancer can reduce lung cancer mortality, but overdiagnosis, false positives and invasive procedures for benign nodules are worrying. We evaluated the utility of positron emission tomography (PET)-CT in characterising indeterminate screening-detected lung nodules. 383 nodules, examined by PET-CT over the first 6 years of the COSMOS (Continuous Observation of Smoking Subjects) study to diagnose primary lung cancer, were reviewed and compared with pathological findings (surgically-treated patients) or follow-up (negative CT for ⩾2 years, considered negative); 196 nodules were malignant. The sensitivity, specificity and accuracy of PET-CT for differentially diagnosing malignant nodules were, respectively, 64%, 89% and 76% overall, and 82%, 92% and 88% for baseline-detected nodules. Performance was lower for nodules found at repeat annual scans, with sensitivity ranging from 22% for nonsolid to 79% for solid nodules (p=0.0001). Sensitivity (87%) and specificity (73%) were high for nodules ⩾15 mm, better (sensitivity 98%) for solid nodules ⩾15 mm. PET-CT was highly sensitive for the differential diagnosis of indeterminate nodules detected at baseline, nodules ⩾15 mm and solid nodules. Sensitivity was low for sub-solid nodules and nodules discovered after baseline for which other methods, e.g. volume doubling time, should be used.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=13; title_english_function_words=3; title_english_share=0.2308; title_reads=english; abstract_words=190; abstract_english_function_words=58; abstract_english_share=0.3053; abstract_reads=english; language_check=metadata_listed