Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Evaluation of Automatic Segmentation Tools on Low-Dose and Ultra-Low-Dose CT Images in PET/CT Scans

Samaneh Mostafapour; Mazarine Van der Galiën; Joyce van Sluis; Adrienne H. Brouwers; Z. Li; Adriaan A. Lammertsma; Charalampos Tsoumpas (2024). European Workshop on Visual Information Processing

DOI 10.1109/euvip61797.2024.10772868

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

The use of Ultra-Low-Dose computed tomography (ULD-CT) in PET/CT imaging is gaining attention due to its potential to significantly reduce radiation exposure, which is crucial for patient safety. Accurate organ segmentation is essential for treatment planning, particularly in radiotherapy where it aids in delineating target volumes and organs at risk. This study investigated the reproducibility of organ segmentation on ULD-CT in PET/CT imaging. In a cohort of 28 patients undergoing [18F]FDG PET/CT scans, segmentation outcomes were compared between standard low-dose CT (LD-CT) and ULD-CT images. Segmentations were performed using the TotalSegmentator and MOOSE tools, and accuracy was quantified using metrics such as the Dice coefficient, Jaccard index, and Hausdorff and Average distance. Results indicated that ULD-CT, despite its significantly reduced radiation dose and increased image noise, achieved comparable segmentation accuracy to LD-CT for most anatomical structures, with Dice coefficients and Jaccard indices maintaining high values across segmented organs. However, lower reproducibility was observed for structures like the kidneys, and aorta, potentially due to the presence of adjacent structures with similar intensities, making accurate boundary delineation more challenging, especially in the noisy ULD-CT images. Quantitative PET analyses, represented by SUVmean and SUVmax, also showed consistent results between LD-CT and ULD-CT reconstructions. However, the segmentation tools exhibited some errors even on the LD-CT images, that means there are areas for further improvement in these tools. Overall, the study emphasizes that ULD-CT does not compromise the use of automatic segmentation tools like TotaSegmentator and Moose, maintaining the clinical utility of PET/CT scans for most anatomical structures while reducing radiation exposure.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=18; title_english_function_words=4; title_english_share=0.2222; title_reads=english; abstract_words=275; abstract_english_function_words=88; abstract_english_share=0.3200; abstract_reads=english; language_check=metadata_listed