Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

[18F]Fluorodeoxyglucose-positron emission tomography screening for lung cancer: a systematic review and meta-analysis

Chun‐Ru Chien; Ji‐An Liang; Jin-Hua Chen; Hsiao-Nin Wang; Cheng‐Chieh Lin; Chih‐Yi Chen; Pin-Hui Wang; Chia‐Hung Kao; Jun‐Jun Yeh (2013). Cancer Imaging

DOI 10.1102/1470-7330.2013.0038

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

RATIONALE AND OBJECTIVES: Although low-dose computed tomography (CT) is a recommended modality for lung cancer screening in high-risk populations, the role of other modalities, such as [(18)F]fluorodeoxyglucose-positron emission tomography (PET), is unclear. We conducted a systematic review to describe the role of PET in lung cancer screening. MATERIALS AND METHODS: A systematic review was conducted by reviewing primary studies focusing on PET screening for lung cancer until July 2012. Two independent reviewers identified studies that were compatible for inclusion/exclusion criteria. The analysis was restricted to English and included studies published since 2000. A descriptive analysis was used to summarize the results, and the pooled diagnostic performance of selective PET screening was calculated by weighted average using individual sample sizes. RESULTS: Among the identified studies (n = 3497), 12 studies were included for analysis. None of the studies evaluated the efficacy of primary PET screening specific to lung cancer. Eight studies focused on primary PET screening for all types of cancer; the detection rates of lung cancer were low. Four studies reported evidence of lung cancer screening programs with selective PET, in which the estimated pooled sensitivity and specificity was 83% and 91%, respectively. CONCLUSIONS: The role of primary PET screening for lung cancer remains unknown. However, PET has high sensitivity and specificity as a selective screening modality. Further studies must be conducted to evaluate the use of PET or PET/computed tomography screening for high-risk populations, preferably using randomized trials or prospective registration. ADVANCES IN KNOWLEDGE: Our meta-analysis indicates that PET has high sensitivity and specificity as a selective screening modality.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=15; title_english_function_words=3; title_english_share=0.2000; title_reads=english; abstract_words=261; abstract_english_function_words=88; abstract_english_share=0.3372; abstract_reads=english; language_check=metadata_listed