Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

HybridFormer: a convolutional neural network-Transformer architecture for low dose computed tomography image denoising

Shanaz Sharmin Jui; Zhitao Guo; Rending Jiang; Jiale Liu; Bohua Li (2025). PeerJ Computer Science

DOI 10.7717/peerj-cs.2952

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
Crossref, OpenAlex
Free full text
Not looked for in this run

Abstract

Low-dose computed tomography (CT) is a potent strategy to minimize X-ray radiation and its detrimental effects on patients. However, reducing radiation significantly boosts noise in reconstructed images, causing blur and obscuring critical tissue details. This obscurity poses significant challenges for doctors in making accurate diagnoses. Traditional techniques like sinogram domain filtration and iterative reconstruction algorithms require inaccessible raw data. Thus, this article introduces HybridFormer, a revolutionary image-denoising model utilizing the Residual Convolution-Swin Transformer Network, designed to enhance images while preserving vital details. Firstly, this algorithm constructs residual convolution for local feature extraction and Swin Transformer for global feature extraction, boosting denoising efficacy. Secondly, to address texture detail errors, we introduced a combined attention transformer unit (CATU) with a cross-channel attentive fusion layer (CCAFL), integrated with residual blocks to form a residual convolution and Swin Transformer Fusion Block (RSTB). Finally, using RSTB, we developed a deep feature refinement module (DFRM) to preserve image details. To avoid smoothing, we combined multi-scale perceptual loss from ResNet-50 with Charbonnier loss into a composite loss function. Validated on the AAPM2016 Mayo dataset, HybridFormer outperformed other state-of-the-art algorithms, achieving improvements of 0.02 dB, 0.16%, and 0.28% in PSNR, SSIM, and FSIM, respectively. Compared with other advanced algorithms, the proposed algorithm achieved the best performance indicators, confirming its superiority.

From Crossref.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=14; title_english_function_words=2; title_english_share=0.1429; title_reads=english; abstract_words=218; abstract_english_function_words=52; abstract_english_share=0.2385; abstract_reads=english; language_check=metadata_listed