Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Ultrasound location of ground-glass opacity during thoracoscopic surgery

Gaetana Messina; Mary Bove; Giovanni Natale; Antonio Noro; Mario Martone; Giorgia Opromolla; Vincenzo Di Filippo; Beatrice Leonardi; Morena Fasano; Rita Polito; Alfonso Fiorelli; Mario Santini; Giovanni Vicidomini (2022). Interactive Cardiovascular and Thoracic Surgery

DOI 10.1093/icvts/ivac234

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

OBJECTIVES: Application of video-assisted thoracoscopy brought lung surgery into the minimally invasive era; the lack of tactile feedback using VATS, remains a disadvantage because surgeons are unable to locate lesions with a finger or device. This study aimed to investigate the effectiveness, the applicability and the utility of intraoperative ultrasound (IU), for the localization of small ground-glass opacity (GGO) lesions in the parenchyma, as a guide in finding their margins in a deflated lung. MATERIALS AND METHODS: We included 15 consecutive patients undergoing diagnostic resection of GGOs via VATS in the Thoracic Surgery Unit of the University of 'Luigi Vanvitelli' of Naples from November 2019 to December 2021. They were under general anaesthesia, when the lung had been collapsed, the probe was placed in the region where the target lesion was thought to reside on the basis of low-dose computed tomography scanning. GGO could be identified their sizes, echo levels and posterior echo was recorded by IU when the lung was completely deflated. RESULTS: We conducted a retrospective single-centre study. All GGOs were identified by IU. The mean size and depth were 14.1 ± 0.5 and 4.8 ± 0.3 mm, respectively. Six (40%) lesions had hyperechoic patterns, 9 (60%) had mixed echogenicity where the hyperechoic patterns were irregularly mixed with hypoechoic patterns. The final diagnoses included 2 (15%) atypical adenomatous hyperplasia; 2 (15%) adenocarcinomas in situ; 3 (23%) minimally invasive adenocarcinomas and 6 (46%) invasive adenocarcinomas. CONCLUSIONS: The results of our study showed that IU could safely and effectively detect GGOs.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=9; title_english_function_words=2; title_english_share=0.2222; title_reads=english; abstract_words=235; abstract_english_function_words=90; abstract_english_share=0.3830; abstract_reads=english; language_check=metadata_listed