Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Evaluation of the prostate cancer and its metastases in the [68Ga]Ga-PSMA PET/CT images: deep learning method vs. conventional PET/CT processing
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
PURPOSE: This study demonstrates the feasibility and benefits of using a deep learning-based approach for attenuation correction in [ 68 Ga]Ga-PSMA PET scans. METHODS: A dataset of 700 prostate cancer patients (mean age: 67.6 ± 5.9 years, range: 45-85 years) who underwent [ 68 Ga]Ga-PSMA PET/computed tomography was collected. A deep learning model was trained to perform attenuation correction on these images. Quantitative accuracy was assessed using clinical data from 92 patients, comparing the deep learning-based attenuation correction (DLAC) to computed tomography-based PET attenuation correction (PET-CTAC) using mean error, mean absolute error, and root mean square error based on standard uptake value. Clinical evaluation was conducted by three specialists who performed a blinded assessment of lesion detectability and overall image quality in a subset of 50 subjects, comparing DLAC and PET-CTAC images. RESULTS: The DLAC model yielded mean error, mean absolute error, and root mean square error values of -0.007 ± 0.032, 0.08 ± 0.033, and 0.252 ± 125 standard uptake value, respectively. Regarding lesion detection and image quality, DLAC showed superior performance in 16 of the 50 cases, while in 56% of the cases, the images generated by DLAC and PET-CTAC were found to have closely comparable quality and lesion detectability. CONCLUSION: This study highlights significant improvements in image quality and lesion detection capabilities through the integration of DLAC in [ 68 Ga]Ga-PSMA PET imaging. This innovative approach not only addresses challenges such as bladder radioactivity but also represents a promising method to minimize patient radiation exposure by integrating low-dose computed tomography and DLAC, ultimately improving diagnostic accuracy and patient outcomes.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=24; title_english_function_words=6; title_english_share=0.2500; title_reads=english; abstract_words=251; abstract_english_function_words=70; abstract_english_share=0.2789; abstract_reads=english; language_check=metadata_listed