Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Low-Dose Scanning Technology Combined with Low-Concentration Contrast Material in Renal Computed Tomography Angiography (CTA): A Preliminary Study
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- Crossref
- Free full text
- Not looked for in this run
Abstract
BACKGROUND This study is to investigate the feasibility of low iodine concentration contrast material (CM) combined with low tube voltage and adaptive statistical iterative reconstruction (ASIR) in renal computed tomography angiography (CTA). MATERIAL AND METHODS A total of 136 patients were enrolled in this prospective trial, and randomly divided into two groups: group A (n=68) and group B (n=68). Group A received 120-kVp and iopromide (370 mg/mL) with filtered back projection (FBP) reconstruction, and group B received 100-kVp and iodixanol (270 mg/mL) with ASIR 40% (ASIR40). An equal iodine dose (300 mg/kg body weight) and the same iodine delivery rate (1,500 mg I/s) were given to all patients. Density, image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured, and the image quality and visualization of renal arteries were scored. Dose-length product (DLP) and CT dose index volume (CTDIvol) were recorded, and effective doses (ED) were calculated. RESULTS There was no significant difference in image noise between groups A and B (p>0.05). The vessel attenuation, SNR, and CNR were significantly higher in group B than group A (all p<0.05). The subjective image quality and visualization of renal artery branches were similar in these two groups (p>0.05). Compared with group A, the CTDIvol, DLP, and ED in group B were decreased by 38.58%, 37.24%, and 37.24%, respectively (p=0.000). CONCLUSIONS Compared with 120-kVp with FBP reconstruction, the protocol of 100-kVp with ASIRP40 reconstruction provided high-quality renal CTA results, which allowed for reduced iodine concentration and decreased radiation dose.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=19; title_english_function_words=3; title_english_share=0.1579; title_reads=english; abstract_words=248; abstract_english_function_words=78; abstract_english_share=0.3145; abstract_reads=english; language_check=metadata_listed