Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Size and Contrast Thresholds for Liver Lesion Detection in Regular and Low-dose CT Examinations: A Reader Study of 2300 Synthetic Lesions Across 100 Patients
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
RATIONALE AND OBJECTIVES: To determine the size and contrast required for liver lesion detection in regular and low-dose computed tomography (CT) examinations. MATERIALS AND METHODS: 100 abdominal CT datasets were retrospectively collected, with 50 originating from vendor A and 50 from vendor B. Half the datasets from each scanner were regular-dose oncologic examinations, the other half were acquired using a low-dose kidney stone protocol. Cylindrical liver lesions with 23 different combinations of diameter and contrast to the surrounding liver were digitally inserted. Seven radiologists assessed lesion detectability in a four-alternative forced choice reading experiment, and image noise was measured within the liver. RESULTS: Lesion detection thresholds at regular dose were at -30, -35, and -70 Hounsfield unit (HU) lesion contrast (vendor A) and -25, -35, and -65 HU (vendor B) for lesions with 15-, 10-, and 5-mm diameter, respectively. At low dose, thresholds were -40 and -45 HU (vendor A) and -40 and -50 HU (vendor B) for 15- and 10-mm lesions, while 5-mm lesions did not reach the detection threshold. Noise levels were 21.5±2.3 HU at regular dose vs 22.2±2.0 HU at low dose for vendor A (P=.06) and 25.9±4.9 HU vs 30.9±3.1 HU for vendor B (P<.001). CONCLUSION: In oncologic CT examinations, liver lesions with diameters of 15-, 10-, and 5-mm require contrasts of -30, -35, and -70 HU, respectively for reliable detection. In low-dose examinations, greater contrasts of -40 and -50 HU are required for lesions measuring 15- and 10-mm, while readers do not reliably detect 5-mm lesions.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=23; title_english_function_words=7; title_english_share=0.3043; title_reads=english; abstract_words=227; abstract_english_function_words=78; abstract_english_share=0.3436; abstract_reads=english; language_check=metadata_listed