Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Assessment of the sacroiliac joint with computed tomography motion analysis: a diagnostic study of 12 patients

Grim Olivecrona; Lena Gordon Murkes; Henrik Olivecrona; Paul Gerdhem (2024). Acta Orthopaedica

DOI 10.2340/17453674.2024.35227

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

BACKGROUND AND PURPOSE: Pain in the sacroiliac joint may be caused by abnormal joint motion. Diagnosis is mainly based on clinical tests. The aims of this study were to examine whether low-dose computed tomography with provocation of the hip could detect sacroiliac joint motion, and to study whether provocation of the hip results in greater sacroiliac joint motion in the ipsilateral than in the contralateral sacroiliac joint. PATIENTS AND METHODS: 12 patients with sacroiliac joint pain were examined with low-dose computed tomography scans of the sacroiliac joint, one with the hips in the neutral position, and one each in provocation with the left or the right hip in a figure-of-4 position. Accuracy was tested by comparing internal rotation of the sacrum with internal rotation in the sacroiliac joint. Motion in the sacroiliac joint was assessed by comparing the position of each of the ilia with the reference, the sacrum. Data is shown as mean with 95% confidence interval (CI). RESULTS: We observed greater motion in the sacroiliac joint than internally in the sacrum, i.e., 0.57° (CI 0.43-0.71) vs. 0.20° (CI 0.11-0.28). The motion of the geometric center of the moving object for the sacroiliac joint was larger on the provoked side; mean difference 0.17 mm (CI 0.01-0.33), P = 0.04. Corresponding figures for rotation were mean difference 0.19° (CI 0.10-0.28), P < 0.001. Compared with the sacrum, the largest motion was seen at the anterior superior iliac spine; mean difference 0.38 mm (CI 0.10-0.66), P = 0.001. CONCLUSION: Provocation in the figure-of-4 position of the hip results in sacroiliac joint motion measurable with computed tomography motion analysis. Provocation of the hip induces larger motion on the ipsilateral than on the contralateral sacroiliac joint.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=15; title_english_function_words=5; title_english_share=0.3333; title_reads=english; abstract_words=270; abstract_english_function_words=108; abstract_english_share=0.4000; abstract_reads=english; language_check=metadata_listed