Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Quantitative analysis of regional lung ventilation and perfusion PET with 68Ga-labelled tracers

Liane Oehme; Klaus Zöphel; Elena Golgor; Michael Andreeff; Gerd Wunderlich; Claudia Brogsitter; Marcelo Gama de Abreu; Jörg Kotzerke (2014). Nuclear Medicine Communications

DOI 10.1097/mnm.0000000000000084

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

INTRODUCTION: The aims of this study were to determine the quantitative parameters of ventilation (V) and perfusion (Q) PET scans assessing V/Q quotients in patients with various lung pathologies, as well as the influence of patient position on regional perfusion patterns. METHODS: Fifty-three patients (24 male and 29 female) underwent lung scintigraphy with (68)Ga-labelled radiopharmaceuticals. (68)Ga Galligas and B20 microspheres used for V and Q imaging were produced in-house. Images were acquired under a standard setup with two emission scans of the whole lung in the supine (S) position (acquisition time 3 min/bed position) on a PET/CT scanner combined with low-dose computed tomography (CT) for attenuation correction. In 27 patients the Q scan was repeated in the prone (P) position. Parametric images were calculated (V/Q, P/S when applicable) for each patient. Patients were grouped according to diagnostic findings, and V/Q ratio distributions were further analysed. Gradients of the regional blood flow in both the supine and prone position were calculated. RESULTS: The results from visual interpretation could be confirmed with parametric images. Voxel-wise V/Q analysis revealed significant differences in descriptive parameters such as median, mean and SD between normal patients and patients with acute and previous pulmonary embolism. Skewness and kurtosis were not significantly different. The effect of gravitation could be demonstrated by significant position-dependent changes of the gradients in the ventral-dorsal and apical-basal directions. CONCLUSION: PET/CT using (68)Ga-labelled tracers allows the application of quantitative procedures to improve functional pulmonary imaging in clinical diagnosis and research.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=13; title_english_function_words=3; title_english_share=0.2308; title_reads=english; abstract_words=259; abstract_english_function_words=85; abstract_english_share=0.3282; abstract_reads=english; language_check=metadata_listed