Example review, open to read without an account Sign in

Literature review · started Nov 18, 2026

Lung cancer screening with low-dose CT

Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.

All studies

Blood‐based detection of lung cancer using cysteine‐rich angiogenic inducer 61 (CYR61) as a circulating protein biomarker: a pilot study

Lucija Ačkar; Swaantje Casjens; Antje Andreas; Irina Raiko; Thomas Brüning; Maria Geffken; Sven Peine; Jens Kollmeier; Georg Johnen; Kai Bartkowiak; Daniel Gilbert Weber; Klaus Pantel (2021). Molecular Oncology

DOI 10.1002/1878-0261.13099

Not decided

Not in the sample the AI screened

Decided by
Nobody yet
Found in
OpenAlex
Free full text
Not looked for in this run

Abstract

Lung cancer is the most often diagnosed cancer and the main cause of cancer deaths in the world compared with other tumor entities. To date, the only screening method for high‐risk lung cancer patients is low‐dosed computed tomography which still suffers from high false‐positive rates and overdiagnosis. Therefore, there is an obvious need to identify biomarkers for the detection of lung cancer that could be used to guide the use of low‐dosed computed tomography or other imaging procedures. We aimed to assess the performance of the protein cysteine‐rich angiogenic inducer 61 (CYR61) as a circulating biomarker for the detection of lung cancer. CYR61 concentrations in plasma were significantly elevated in 87 lung cancer patients (13.7 ± 18.6 ng·mL −1 ) compared with 150 healthy controls (0.29 ± 0.22 ng·mL −1 ). Subset analysis stratified by sex revealed increased CYR61 concentrations for adenocarcinoma and squamous cell carcinoma in men compared with women. For male lung cancer patients versus male healthy controls, the sensitivity was 84% at a specificity of 100%, whereas for females, the sensitivity was 27% at a specificity of 99%. The determination of circulating CYR61 protein in plasma might improve the detection of lung cancer in men. The findings of this pilot study support further verification of CYR61 as a biomarker for lung cancer detection in men. Additionally, CYR61 is significantly elevated in women but sensitivity and specificity for CYR61 are too low for the improvement of the detection of lung cancer in women.

From OpenAlex.

The criteria

  • Include if: The document is in English.
    Meets (checked by an automatic rule)

    What the rule found: language_in: language=en; title_words=20; title_english_function_words=4; title_english_share=0.2000; title_reads=english; abstract_words=235; abstract_english_function_words=92; abstract_english_share=0.3915; abstract_reads=english; language_check=metadata_listed