Literature review · started Nov 18, 2026
Lung cancer screening with low-dose CT
Example This is an example review. You can read every page, but not change it. The AI screen in this example ran on a sample of 23 of the 9,965 studies found, so most studies show as not screened.
Deep learning model for automatic detection of incidental adrenal abnormalities on low-dose computed tomography images
Not decided
Not in the sample the AI screened
- Decided by
- Nobody yet
- Found in
- OpenAlex
- Free full text
- Not looked for in this run
Abstract
BACKGROUND: To investigate the feasibility of employing deep learning models for automated segmentation and classification of adrenal incidental abnormalities on low-dose CT images. METHODS: Four distinct CT cohorts were retrospectively collected for deep learning models development (cohort A, n = 2574; cohort B, n = 1205), internal evaluation (cohort C, n = 3681), and external evaluation (cohort D, n = 779). Two experienced uroradiologists independently reviewed the CT images and labeled the adrenal glands as normal or abnormal based on predefined criteria encompassing both density and morphological abnormalities, with any discrepancies resolved through consultation. The model development cohorts were divided into a training set, a validation set, and a test set. Deep learning models for segmentation and classification were trained and evaluated on internal and external sets, with the dice similarity coefficient (DSC), area under precision-recall curves (AUPRC), and area under receiver operating characteristic curves (AUROC) as evaluation metrics. Adrenal descriptions from radiology reports were extracted to compare with the model's performance. RESULTS: For adrenal gland segmentation, the DSC values for the test set, internal validation cohort, and external validation cohort were 0.839 (IQR: 0.783-0.871), 0.870 (IQR: 0.819-0.902), and 0.799 (IQR: 0.729-0.849), respectively. For adrenal gland classification, the AI model achieved AUPRC values of 0.913, 0.753, and 0.927 in the test set, internal validation cohort, and external validation cohort, respectively, outperforming routine radiology reporting (AUPRC: 0.809, 0.708, 0.591; all P < 0.05). Corresponding AUROC values were 0.956, 0.942, and 0.977 for the AI model, which also outperformed routine radiology reporting (AUROC: 0.889, 0.705, 0.551; all P < 0.05). CONCLUSIONS: The deep learning models showed promise in automated adrenal segmentation and classification, highlighting AI's potential to improve detection of adrenal abnormalities in LDCT scans. TRIAL REGISTRATION: This study has been registered on ClinicalTrials.gov on August 25, 2025, with the unique identifier NCT07198152.
From OpenAlex.
The criteria
-
Include if: The document is in English.
Meets (checked by an automatic rule)What the rule found: language_in: language=en; title_words=16; title_english_function_words=3; title_english_share=0.1875; title_reads=english; abstract_words=274; abstract_english_function_words=81; abstract_english_share=0.2956; abstract_reads=english; language_check=metadata_listed